Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VT GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VT GROUP in GENERAL DYNAMICS - NASSCO NORFOLK ONBOARD USS OAK HILL 200 LIGON STREET, NORFOLK, VA 23523 (NAICS 336611). OSHA activity number 341932937.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VT Group — free Get an email when a new federal OSHA severe-injury report for VT Group is published. One employer, no account, unsubscribe in one click.
Establishment
VT GROUP
Site address
GENERAL DYNAMICS - NASSCO NORFOLK ONBOARD USS OAK HILL 200 LIGON STREET
City
NORFOLK
State
VA
ZIP
23523
Mailing
2505 INTERNATIONAL PARKWAY, VIRGINIA BEACH, VA 23452
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
300
Ownership type
A

1 citation on file for this inspection.

1915.56 B02

Other-than-serious 1 instance 1 exposed
Issued
Apr 25, 2017
Penalty
Initial $7,696 · Current $3,848 Reduced
29 CFR 1915.56(b)(2): Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected.    (a)   Date of Violation: On or about 11-23-2016 and times prior thereto, VT Milcom, Inc. was located at General Dynamics - Nassco Norfolk 200 Ligon Street Norfolk, VA 23523; onboard USS Oak Hill, in the main Radio Room, space 04-30-0-C, an employee was exposed to an electric shock hazard while using a welding lead with a damaged area of cable with exposed electrical conductors covered by electrical tape within 17 inches of the electrode holder.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $3848
  • — Z (S) $7696

View VT Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341932937.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.