WASHINGTON, DC —
OSHA Inspection: PROUGH'S HOME IMPROVEMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROUGH'S HOME IMPROVEMENT in 4813 BLAGDEN AVE NW, WASHINGTON, DC 20004 (NAICS 238170). OSHA activity number 341936581.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROUGH'S HOME IMPROVEMENT
- Site address
- 4813 BLAGDEN AVE NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20004
- Mailing
- 2810 6TH STREET, BALTIMORE, MD 21219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 E01
- Issued
- Feb 15, 2017
- Abate by
- Feb 24, 2017
- Penalty
- Initial $3,802 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) On or about October 26, 2016; front of residential home; employees while working on a ladder-jack scaffold system were exposed to a 15 foot fall while accessing or leaving the working platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1600
- — Z (S) $3802
1926.451 F06
- Issued
- Feb 15, 2017
- Abate by
- Feb 24, 2017
- Penalty
- Initial $2,770 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). On or about October 26, 2016; front of the residential home; the employer had set-up a ladder-jack scaffold system approximated 2 feet from the power line coming into the home exposing employees to a shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $2770
1926.451 G01 I
- Issued
- Feb 15, 2017
- Abate by
- Feb 24, 2017
- Penalty
- Initial $3,802 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: On or about October 26, 2019; front of residential home; employees while working on a ladder-jack scaffold system did not have fall protection exposing them to a 15 foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1600
- — Z (S) $3802
More inspections in this industry (NAICS 238170)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341936581.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.