Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BECKY PAINTER

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BECKY PAINTER in 408 E RIVER ST, ELKLAND, PA 16920 (NAICS 311611). OSHA activity number 341937621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Becky Painter — free Get an email when a new federal OSHA severe-injury report for Becky Painter is published. One employer, no account, unsubscribe in one click.
Establishment
BECKY PAINTER
Site address
408 E RIVER ST
City
ELKLAND
State
PA
ZIP
16920
Mailing
408 E RIVER ST, ELKLAND, PA 16920
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
Employees
8
Ownership type
A

2 citations on file for this inspection.

1910.179 J03

Deleted Serious Gravity 1 3 instances 3 exposed
Issued
Jan 24, 2017
Abate by
Mar 13, 2017
Penalty
Initial $2,173 · Current $0 Reduced
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  a) Kill Floor: The Harrington 2-ton overhead crane had not been subject to a periodic inspection, on or about November 29, 2016.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $2173

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Jan 24, 2017
Abate by
Mar 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cord and cable was used as a substitute for the fixed wiring of a structure:  a) Kill Floor: An extension cord was used in place of permanent wiring to provide power to a 1500 lb hoist installed on the ceiling, on or about November 29, 2016.  ABATEMENT CERTIFICATION REQUIRED