Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRAKE CHECK

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRAKE CHECK in 11429 W. LOOP 1604, SAN ANTONIO, TX 78254 (NAICS 811191). OSHA activity number 341937928.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brake Check — free Get an email when a new federal OSHA severe-injury report for Brake Check is published. One employer, no account, unsubscribe in one click.
Establishment
BRAKE CHECK
Site address
11429 W. LOOP 1604
City
SAN ANTONIO
State
TX
ZIP
78254
Mailing
11429 TX-1604 LOOP, SAN ANTONIO, TX 78254
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
188
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 16 exposed
Issued
Mar 17, 2017
Abate by
Apr 6, 2017
Penalty
Initial $11,408 · Current $4,500 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:    Bay 3:  On or about November 29, 2016, and at times prior thereto, employees engaged in lowering a vehicle using an automotive lift were exposed to caught-in hazards, while the lift was being operated with the safety latch cover removed and an employee holding a moving part.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $11408

1910.147 C01

Serious Gravity 10 1 instance 16 exposed
Issued
Mar 17, 2017
Abate by
Apr 6, 2017
Penalty
Initial $11,408 · Current $4,500 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      Maintenance Bay:  On or about November 29, 2016, and at times prior thereto, an employee engaged in maintenance on a vehicle lift was exposed to caught-in hazards associated with the unexpected release of stored energy, while not locking out the equipment.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $11408

View Brake Check's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341937928.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.