OSHA Inspection: RESTAURANT EQUIPMENT SERVICE GROUP LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RESTAURANT EQUIPMENT SERVICE GROUP LLC in 221 S WASHINGTON ST, NAPERVILLE, IL 60540 (NAICS 811310). OSHA activity number 341938181.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Restaurant Equipment Service Group LLC — free Get an email when a new federal OSHA severe-injury report for Restaurant Equipment Service Group LLC is published. One employer, no account, unsubscribe in one click.
Site address
221 S WASHINGTON ST
City
NAPERVILLE
State
IL
ZIP
60540
Mailing
50 EISENHOWER LANE N, LOMBARD, IL 60148
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
46
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 19, 2017
Abate by
May 10, 2017
Penalty
Initial $8,149 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    On or about November 25, 2016, employees were exposed to amputation hazards while performing maintenance activities on a restaurant roof top HVAC unit.  The employer's written lockout/tagout program did not include specific procedural steps that clearly stated the necessary steps for machine shut down, the isolation and the securing of hazardous energy, nor did the program provide procedural steps for the placement and removal of lockout devices.  There were no specific requirements or procedures to determine and verify that all hazardous energy was dissipated from the mechanical transmission system or other systems of the unit.        Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $8149

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2017
Abate by
May 10, 2017
Penalty
Initial $8,149 · Current $7,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about November 25, 2016, employees were exposed to amputation hazards while performing maintenance activities on a restaurant roof top HVAC unit.  The employer did not conduct a periodic inspection of the energy control procedure, at least annually, to ensure that the procedures and the requirements of the standard were being followed.        Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $7000
  • — Z (S) $8149

1910.147 C07 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2017
Abate by
May 10, 2017
Penalty
Initial $8,149 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  On or about November 25, 2016, employees were exposed to amputation hazards while performing maintenance activities on a restaurant roof top HVAC unit.  The employer did not provide adequate training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.    Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $0
  • — Z (S) $8149

1910.147 D05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2017
Abate by
May 10, 2017
Penalty
Initial $11,408 · Current $10,000 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:    On or about November 25, 2016, an employee was exposed to amputation hazards while performing maintenance activities on a restaurant roof top HVAC unit when attempting to remove a sheet metal cover to gain access to power transmission components that remained energized.  The employer did not ensure hazardous energy controls were implemented and utilized so that residual hazardous energy was relieved prior to starting work on power transmission components of a ventilation exhaust system.        Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $10000
  • — Z (S) $11408