Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WINDOW SPECIALISTS INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WINDOW SPECIALISTS INC. in 600 MAIN ST, LYKENS, PA 17048 (NAICS 238150). OSHA activity number 341940385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Window Specialists INC. — free Get an email when a new federal OSHA severe-injury report for Window Specialists INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 MAIN ST
City
LYKENS
State
PA
ZIP
17048
Mailing
188 ERIE STREET, LANCASTER, NY 14086
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
25
Ownership type
A

1 citation on file for this inspection.

1926.501 B14

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 16, 2017
Penalty
Initial $3,622 · Current $2,535 Reduced
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chute openings) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:     a)  Construction Site at 600 Main St., Lykens, PA: South side of "Hotel" building 2nd floor through 4th floor had 3 window openings, all with 32-33 inch high window sills and did not have a 42 inch high guardrail in place therefore exposing employees to fall hazards on or about October 25, 2016.     No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2535.4
  • — Z (S) $3622

View Window Specialists INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341940385.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.