SOUTH FALLSBURG, NY —
OSHA Inspection: STEINGART ASSOCIATES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STEINGART ASSOCIATES, INC. in 5211 MAIN STREET, SOUTH FALLSBURG, NY 12779 (NAICS 323110). OSHA activity number 341940542.
Where did this inspection happen?
- Establishment
- STEINGART ASSOCIATES, INC.
- Site address
- 5211 MAIN STREET
- City
- SOUTH FALLSBURG
- State
- NY
- ZIP
- 12779
- Mailing
- 5211 MAIN STREET, P.O. BOX 460, SOUTH FALLSBURG, NY 12779
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A02
- Issued
- Penalty
- Initial $1817.00 · Current $1090.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) Worksite - On or prior to November 29, 2016, an employee operated a Heidelberg (M.-NO. 960914) machine used for printing without the guards affixed to the machine exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $1090.2
- — Z (S) $1817
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Basement - On or about November 29, 2016, a relocatable power tap (RPT) or power strip was connected with or "daisy chained" to another RPT by a permanent extension cord. The RPTs both had equipment plugged into them including a radio.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Basement - On or about November 29, 2016, a permanent extension cord was used to connect or "daisy chain" together two relocatable power taps (RPTs) or power strips. The RPTs both had equipment plugged into them including a radio.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at STEINGART ASSOCIATES, INC.
SOUTH FALLSBURG, NY—1996-04-18 00:00:00
STEINGART ASSOCIATES INC.
View STEINGART ASSOCIATES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323110)
MINNEAPOLIS, MN—2026-05-20
111284 - MARTH GROUP LLC DBA ENPOINTE
GLENDALE, KY—2026-02-04
68801 - PG-GERALD LLC
PORTLAND, OR—2026-01-16
317742947 - PEP PRINTING INC
MINNEAPOLIS, MN—2025-11-18
110299 - OMEGA LITHOGRAPH INC
BELLINGHAM, WA—2025-09-05
WA317987718 - CAPITOL CITY PRESS INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341940542.