TAMPA, FL —
OSHA Inspection: HITMASTER GRAPHICS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HITMASTER GRAPHICS, LLC in 1706 W. FIG ST., TAMPA, FL 33606 (NAICS 323113). OSHA activity number 341940757.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HITMASTER GRAPHICS, LLC
- Site address
- 1706 W. FIG ST.
- City
- TAMPA
- State
- FL
- ZIP
- 33606
- Mailing
- 1706 W. FIG ST., TAMPA, FL 33606
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 50
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 16, 2016
- Abate by
- Jan 23, 2017
- Penalty
- Initial $7,482 · Current $7,482
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) For the textile presses at the facility, as observed on or about 11/30/2016, an energy control program was not established to protect employees from hazardous energy while performing maintenance/servicing of the machines, such as, but not limited to, cleaning print carriages, lubrication, and cleaning out electrical boxes of the presses.
Recent events (2)
- — Z $19012
- — Z (S) $7482
1910.147 D03
- Issued
- Dec 16, 2016
- Abate by
- Dec 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) For the textile presses at the facility, employees performed maintenance/servicing tasks such as, but not limited to, cleaning print carriages and lubrication while the presses were not isolated from all energy sources. Employees would perform maintenance/servicing tasks after switching a toggle switch to power down the presses and were not de-energizing the press at the breaker boxes or physically unplugging them from wall outlets. Two of the presses were cord and plug and three were hard wired into breaker boxes.
Recent events (2)
- — Z $0
- — Z (S) $0
1904.29 A
- Issued
- Dec 16, 2016
- Abate by
- Dec 29, 2016
- Penalty
- Initial $700 · Current $700
General-duty citation text
29 CFR 1904.29(a): A Log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or Summary of Work-Related Injuries and Illnesses, (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment: a) On 09/22/2016, an employee working on a textile press machine sustained injuries which resulted in medical treatment and 3 days away from work. The injury was not recorded on an OSHA Form 300 and/or and OSHA Form 301. The OSHA 300 and 301 forms were not being kept by the employer.
Recent events (1)
- — Z (O) $700
1910.303 F02
- Issued
- Dec 16, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) For the Hitmaster Graphics facility, as observed on or about 11/30/2016, branch circuits which powered textile presses such as, but not limited to, two Sportsmen presses and a Challenger press, were not labeled to show which breakers supplied electric power to the presses.
Recent events (1)
- — Z (O) $0
1910.303 G01 II
- Issued
- Dec 16, 2016
- Abate by
- Dec 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) For the closet area, as observed on or about 11/30/2016, two breaker boxes and a main disconnect were blocked by the storage of materials such that access to the electrical boxes and disconnect was impeded.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Dec 16, 2016
- Abate by
- Jan 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) For the Gauntlet press, as observed on or about 11/30/2016, a temporary flexible cord was used as permanent wiring to provide power to the press.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Dec 16, 2016
- Abate by
- Dec 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) For the textile press room, as observed on or about 11/30/2016, a drop down pendant at the Diamondback Press had its outer insulation removed at the plug such that there was the potential for strain to be placed on the inner conductors.
Recent events (1)
- — Z (O) $0
More inspections at Hitmaster Graphics, LLC
View Hitmaster Graphics, LLC's full OSHA safety record →
More inspections in this industry (NAICS 323113)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341940757.