Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KTI, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of KTI, INC. in 3 THOMPSON ROAD, EAST WINDSOR, CT 06088 (NAICS 811310). OSHA activity number 341942639.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KTI, INC. — free Get an email when a new federal OSHA severe-injury report for KTI, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KTI, INC.
Site address
3 THOMPSON ROAD
City
EAST WINDSOR
State
CT
ZIP
06088
Mailing
3 THOMPSON ROAD, EAST WINDSOR, CT 06088
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
29
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 7 instances 2 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $5,070 · Current $3,549 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Through out the shop;  On or about 11/30/16, lock out/tag out procedures were not developed to control the hazardous energies on each electron beam welding tool.  Employees that work on the electron beam welders need to control the following energies that can be potentially hazardous: electrical, which also controls the ionizing radiation hazard; vacuum pumps; cooling water.  Each machine needs for these energies to be controlled in different locations and sometimes by different means.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

1910.252 B02 I B

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $5,070 · Current $3,549 Reduced
29 CFR 1910.252(b)(2)(i)(B): Goggles or other suitable eye protection were not used during all gas welding or oxygen cutting operations:  Shop, continuous weld electron beam area;  On or about 11/30/16, employees were using oxyacetylene welders to attach spooling strips of metal without any eye protection from the uv light produced.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $3,802 · Current $2,661 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Shop, next to the vacuum chamber;  On or about 11/30/16, a power strip was daisy-chained to another multi-tap box and an extension cord and mounted onto a work bench.
Recent events (2)
  • — I (S) $2661.4
  • — Z (S) $3802

1910.1096 D01

Serious Gravity 5 7 instances 21 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $5,070 · Current $3,549 Reduced
29 CFR 1910.1096(d)(1): The employer did not make such surveys as necessary to evaluate the radiation hazards incident to the production, use, release, disposal or presence of radioactive materials or other sources of radiation under a specific set of conditions:  Through out the shop;  On or about 11/30/16, radiation surveys conducted around electron beam welders did not indicate the location of measurements relative to the source.  The survey did not include measurements for multiple locations around the source to ensure that there were not leaks in the shielding.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

1910.1200 E01

Serious Gravity 1 1 instance 20 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $3,802 · Current $2,661 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Throughout the shop;  On or about 11/30/16, the employer did not have a written hazard communication program that was updated to meet the requirements under the new GHS standard.  Employees throughout the shop use acetone to clean metals.
Recent events (2)
  • — I (S) $2661.4
  • — Z (S) $3802

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Throughout the shop;  On or about 11/30/16, the employer did not provide hazard communication training that was updated to meet the requirements under the new GHS standard.  Employees throughout the shop use acetone to clean metals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01

Other-than-serious 1 instance 1 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Shop, near vacuum storage;  On or about 11/30/16, a knockout was missing on the electrical control box for the vacuum storage unit in the shop.   The digital readout on the front of the box indicated that the box had power to it at the time of the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Jan 25, 2017
Abate by
Mar 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  Shop, near vacuum storage unit;  On or about 11/30/16, a power strip was in use in the shop that had the cable pulled away from the plug strip, exposing the internal wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0