OSHA Inspection: D H SCHMIDT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D H SCHMIDT in 101 BOONE HILLS DRIVE, SAINT PETERS, MO 63376 (NAICS 337110). OSHA activity number 341946028.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D H Schmidt — free Get an email when a new federal OSHA severe-injury report for D H Schmidt is published. One employer, no account, unsubscribe in one click.
Establishment
D H SCHMIDT
Site address
101 BOONE HILLS DRIVE
City
SAINT PETERS
State
MO
ZIP
63376
Mailing
101 BOONE HILLS DRIVE, SAINT PETERS, MO 63376
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
24
Ownership type
A

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 14, 2016
Penalty
Initial $3,563 · Current $2,494 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:   On 12/01/2016, employees from D H Schmidt, located at 101 Boone Hills Drive, St. Peters, MO, were exposed to hazards at the point of operation created rotating parts.  The Hendricks Panel Saw had approximately 1-3/4 inches of the saw blade unguarded at its point of operation.
Recent events (2)
  • — I (S) $2494.1
  • — Z (S) $3563

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 14, 2016
Penalty
Initial $1,817 · Current $1,272 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:   On 12/01/2016, D H Schmidt, located at 101 Boone Hills Drive, St. Peters, MO, employee(s) were exposed to hazards such as those created by an airline used for cleaning purposes above 30 psi.  This particular wand and airline was located at Post 13.
Recent events (2)
  • — I (S) $1271.9
  • — Z (S) $1817

1910.147 C04 I

Other-than-serious 4 instances 1 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance:   On 12/01/2016, D H Schmidt, located at 101 Boone Hills Drive, St. Peters, MO, had not adequately developed, documented and utilized proper procedures for the control of potentially hazardous energy.  The following is a list of machines located in the plant requiring an adequately written procedure:  #731 CNC HolzHer Unimaster;  #1037 Murphy Rodgers Dust Collector (CNC HolzHer);  #002 Panel Saw HolzHer;   and #0443 Powermatic Table Saw.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 4 instances 1 exposed
Issued
Dec 14, 2016
Abate by
Feb 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:   On 12/01/2016, D H Schmidt, located at 101 Boone Hills Drive, St. Peters, MO, had not completed all their required reviews of their LO/TO Program on an at least annual basis.  No one reviewed their procedures for any deviations or inadequacies.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View D H Schmidt's full OSHA safety record →