Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERMA SEAL INSULATION SYSTEMS INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of THERMA SEAL INSULATION SYSTEMS INC. in 641 NW12TH AVE, MIAMI, FL 33116 (NAICS 238190). OSHA activity number 341947448.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Therma Seal Insulation Systems INC. — free Get an email when a new federal OSHA severe-injury report for Therma Seal Insulation Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
641 NW12TH AVE
City
MIAMI
State
FL
ZIP
33116
Mailing
5900 AUSTRAILIAN AVE. 111, WEST PALM BEACH, FL 33407
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Abate by
Mar 23, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced

Hazardous substances 9130

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)  On or about 12/2/2016, at the above address jobsite, the employer did not provide a medical evaluation for employees who were required to wear an air-purifying 3M respirator while mixing fireproofing material.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1910.134 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 9130

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103)  On or about 12/2/2016, at the above address jobsite, the employer did not provide a fit-test for employees who were required to wear an air-purifying 3M respirator while mixing fireproofing material.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Abate by
Mar 23, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced

Hazardous substances 9130

29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59)   On or about 12/13/2016, at the above address jobsite, the employer did not develop or implement a written hazard communication program for employees who were exposed to chemicals such as but not limited to silica, when mixing fireproofing materials.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1910.1200 H03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Abate by
Mar 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 9130

29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:  (Construction Reference: 1926.59)  On or about 12/13/2016, at the above address jobsite, an employee adding bags of Southwest fireproofing type 5GP to a mixer, was not trained on the health hazards associated with silica exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.55 A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Abate by
Mar 23, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced

Hazardous substances 9130

29 CFR 1926.55(a): Employee(s) were exposed to materials (Particulates Not Otherwise Regulated) at concentrations above the 5 milligram per cubic meter (mg/m3) as specified in the Threshold Limit Values of Airborne Contaminants for 1970 of the American Conference of Governmental Industrial Hygienists:  On or about 12/13/2016, at the above address jobsite, an employee was exposed to an 8 hour time-weighted average of 19.608 mg/m3 of particulates not otherwise regulated for a sampling time of 375 minutes during mixing processes at the jobsite. The remaining un-sampled time was considered as zero exposure.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1926.55 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2017
Abate by
Mar 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 9130

29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s):  On or about 12/13/2016, at the above address jobsite, the employer did not use feasible engineering and administrative controls to protect an employee who was exposed to an 8 hour time-weighted average of 19.608 mg/m3 of particulates not otherwise regulated (PNOR) during the fireproof mixing processes at the jobsite.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Therma Seal Insulation Systems INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341947448.