MIAMI, FL —
OSHA Inspection: THERMA SEAL INSULATION SYSTEMS INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of THERMA SEAL INSULATION SYSTEMS INC. in 641 NW12TH AVE, MIAMI, FL 33116 (NAICS 238190). OSHA activity number 341947448.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THERMA SEAL INSULATION SYSTEMS INC.
- Site address
- 641 NW12TH AVE
- City
- MIAMI
- State
- FL
- ZIP
- 33116
- Mailing
- 5900 AUSTRAILIAN AVE. 111, WEST PALM BEACH, FL 33407
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 E01
- Issued
- Feb 27, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $2,716 · Current $1,630 Reduced
9130
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) On or about 12/2/2016, at the above address jobsite, the employer did not provide a medical evaluation for employees who were required to wear an air-purifying 3M respirator while mixing fireproofing material.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1910.134 F01
- Issued
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103) On or about 12/2/2016, at the above address jobsite, the employer did not provide a fit-test for employees who were required to wear an air-purifying 3M respirator while mixing fireproofing material.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 27, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $2,716 · Current $1,630 Reduced
9130
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) On or about 12/13/2016, at the above address jobsite, the employer did not develop or implement a written hazard communication program for employees who were exposed to chemicals such as but not limited to silica, when mixing fireproofing materials.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1910.1200 H03 II
- Issued
- Feb 27, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: (Construction Reference: 1926.59) On or about 12/13/2016, at the above address jobsite, an employee adding bags of Southwest fireproofing type 5GP to a mixer, was not trained on the health hazards associated with silica exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.55 A
- Issued
- Feb 27, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $2,716 · Current $1,630 Reduced
9130
General-duty citation text
29 CFR 1926.55(a): Employee(s) were exposed to materials (Particulates Not Otherwise Regulated) at concentrations above the 5 milligram per cubic meter (mg/m3) as specified in the Threshold Limit Values of Airborne Contaminants for 1970 of the American Conference of Governmental Industrial Hygienists: On or about 12/13/2016, at the above address jobsite, an employee was exposed to an 8 hour time-weighted average of 19.608 mg/m3 of particulates not otherwise regulated for a sampling time of 375 minutes during mixing processes at the jobsite. The remaining un-sampled time was considered as zero exposure.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1926.55 B
- Issued
- Feb 27, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s): On or about 12/13/2016, at the above address jobsite, the employer did not use feasible engineering and administrative controls to protect an employee who was exposed to an 8 hour time-weighted average of 19.608 mg/m3 of particulates not otherwise regulated (PNOR) during the fireproof mixing processes at the jobsite.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Therma Seal Insulation Systems INC.
View Therma Seal Insulation Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341947448.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.