ROCHESTER, WA —
OSHA Inspection: LUCKY EAGLE CASINO
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of LUCKY EAGLE CASINO in 12888 188TH AVE. SW, ROCHESTER, WA 98579 (NAICS 721120). OSHA activity number 341956225.
Where did this inspection happen?
- Establishment
- LUCKY EAGLE CASINO
- Site address
- 12888 188TH AVE. SW
- City
- ROCHESTER
- State
- WA
- ZIP
- 98579
- Mailing
- 12888 188TH AVE. SW, ROCHESTER, WA 98579
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 800
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.215 A04
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $5,432 · Current $3,802 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: A) In the wood shop and the , there was bench grinders that did not have a work rest installed for one of the grinder. B) In the work shop there was a bench grinder where the work rest for the other grinder wheel was 5/8 of an inch from the surface of the wheel.
Recent events (2)
- — I (S) $3802.4
- — Z (S) $5432
1910.215 B09
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: A) There was a bench grinder in the wood shop that had a missing tongue guard over one wheel. B) There was a bench grinder in the workshop that had its tongue guard 1/2 inch from the wheel surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $7,243 · Current $5,070 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: A) The power cord to a wall mounted oven in the snack bar storage room had its outer conduit pulled out revealing the conductors .
Recent events (2)
- — I (S) $5070.1
- — Z (S) $7243
1910.305 G01 IV B
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: A) In the warehouse area, a flexible extension cord was plugged into a wall outlet, and ran all the way through the ceiling, and back down the other side of the room where it was plugged into a device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. A) In the back portion of the event center stage, there was a storage closet, that had equipment stored above it. The load rating for the ceiling of the closet was not posted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: A) The employer was unable to provide a written personal protective equipment analysis for the facility.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A) In the area behind the stage at the event center, there was a fire extinguisher left on the floor near the exit, and was not mounted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1030 C01 I
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure: A) The employer did not provide a bloodborne pathogens exposure control plan even though some employees responded to medical incidents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Apr 21, 2017
- Abate by
- Jun 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program.: A) Employees throughout the facility worked with chemicals, however the employer did not provide a chemical hazard communication program.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lucky Eagle Casino
View Lucky Eagle Casino's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341956225.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.