Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. SPICE MILL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. SPICE MILL, INC. in 4537 W. FULTON STREET, CHICAGO, IL 60624 (NAICS 311942). OSHA activity number 341956795.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Spice Mill, INC. — free Get an email when a new federal OSHA severe-injury report for U.S. Spice Mill, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4537 W. FULTON STREET
City
CHICAGO
State
IL
ZIP
60624
Mailing
4537 W. FULTON STREET, CHICAGO, IL 60624
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311942
Employees
16
Ownership type
A

4 citations on file for this inspection.

1910.134 C02

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 7, 2017
Abate by
Jun 23, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.134(c)(2): The employer did not develop and implement a respiratory protection program in accordance with sections i and ii of this paragraph (c)(2) for employees who chose to wear respirators where respirator use was not required:    a.  On or about December 5, 2016, in the facility, employees were provided tight fitting negative pressure respiratory protection.  Employees were exposed to respiratory hazards when the employer failed to establish and implement a written respiratory protection program.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.147 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 7, 2017
Abate by
Jun 23, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a.  On or about December 5, 2016, in the facility, employees were required to perform maintenance activities including but not limited to changing filters.  The employer did not have a written lock out/tag out program which included energy control procedures, employee training and periodic inspections of the program.  The employees were thereby exposed to the hazards associated with the unexpected energizing or start up of machines and equipment.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.212 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 7, 2017
Abate by
Apr 13, 2017
Penalty
Initial $5,070 · Current $2,535 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a.  On or about November 28, 2016, in the facility, the auger on Cumin Mill #10 did not have a guard, thereby exposing employees to rotating parts.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 7, 2017
Abate by
Apr 13, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:    a.  On or about December 5, 2016, on the forth floor, an electrical cord used to charge a powered industrial vehicle had damaged insulation and was without a ground fault circuit interrupter, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341956795.