OSHA Inspection: HECTOR JESUS MORALES ADAME

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HECTOR JESUS MORALES ADAME in 2925 SOUTHWICK DR., CUMMING, GA 30041 (NAICS 238160). OSHA activity number 341959609.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hector Jesus Morales Adame — free Get an email when a new federal OSHA severe-injury report for Hector Jesus Morales Adame is published. One employer, no account, unsubscribe in one click.
Site address
2925 SOUTHWICK DR.
City
CUMMING
State
GA
ZIP
30041
Mailing
506 LIA HILLS DR., NORCROSS, GA 30071
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1903.19 D

Other-than-serious 1 instance 3 exposed
Issued
Aug 28, 2017
Abate by
Sep 22, 2017
Penalty
Initial $305 · Current $305
29 CFR 1903.19: In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    On or about at 12/8/16 located at Southwick Dr., Cumming, GA., Employer failed to provide abatement of violations (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.
Recent events (1)
  • — Z (O) $305

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2017
Abate by
Mar 9, 2017
Penalty
Initial $1,630 · Current $1,630
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  On or about at 12/8/16 located at Southwick Dr., Cumming, GA: Employees were installing tar paper and roofing shingles on to the 8/12 pitch roof on the house that was under construction while on ridge top of the roof approximately 30  foot from the lower level. Tar paper and Shingles were falling back down to the ground, employees were observed without hard hats exposing them to a struck by hazards.
Recent events (1)
  • — Z (S) $1630

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 10, 2017
Abate by
Mar 9, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about at 12/8/16 located at Southwick Dr., Cumming, GA: Employees were roofing an house that was under construction while installing tar paper and roofing shingles and while working at the edge, the employer did not ensure that fall protection was used by his employees while exposed to fall hazards of approximately up to 30- feet.
Recent events (1)
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 10, 2017
Abate by
Mar 9, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about at 12/8/16 located at Southwick Dr., Cumming, GA., Employees were observed and exposed to fall hazards, while roofing a new house, employees were using a portable extension ladder to gain access to the roof, and the ladder was only 18- inches above the landing surface.
Recent events (1)
  • — Z (S) $3803

View Hector Jesus Morales Adame's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341959609.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.