TEANECK, NJ —
OSHA Inspection: BRODERS CONSTRUCTION CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRODERS CONSTRUCTION CO. in 534 LINDEN AVENUE, TEANECK, NJ 07666 (NAICS 238160). OSHA activity number 341959880.
Where did this inspection happen?
- Establishment
- BRODERS CONSTRUCTION CO.
- Site address
- 534 LINDEN AVENUE
- City
- TEANECK
- State
- NJ
- ZIP
- 07666
- Mailing
- 80 HOWE AVENUE, PASSAIC, NJ 07055
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $3259.00 · Current $3259.00
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: A) Exterior, Roof Level of house: Employees were exposed to eye/face injuries while using pneumatic nail guns and were not protected with any type of eye/face protection, on or about November 9th, 2016.
Recent events (1)
- — Z (S) $3259
1926.501 B13
- Issued
- Penalty
- Initial $3259.00 · Current $3259.00
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) A) Exterior, 1st level Roof of house: Employees were exposed to fall hazards of approximately 12 feet while engaged in roofing work on the roof of a house without a means of fall protection in place, on or about November 9th, 2016.
Recent events (1)
- — Z (S) $3259
1926.1053 B01
- Issued
- Penalty
- Initial $3259.00 · Current $3259.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A) Exterior, Roof Level: Employees were exposed to fall hazards of approximately 12 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about November 9th, 2016.
Recent events (1)
- — Z (S) $3259
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341959880.