Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANK DONIO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FRANK DONIO INC. in 692 EGG HARBOR ROAD., HAMMONTON, NJ 08037 (NAICS 445230). OSHA activity number 341965689.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Frank Donio INC. — free Get an email when a new federal OSHA severe-injury report for Frank Donio INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FRANK DONIO INC.
Site address
692 EGG HARBOR ROAD.
City
HAMMONTON
State
NJ
ZIP
08037
Mailing
692 EGG HARBOR ROAD., HAMMONTON, NJ 08037
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445230
Employees
130
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $8,149 · Current $6,500 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):       a) Frank Donio Inc. - Throughout the production Area: The energy control procedures were not specific for each individual type of machines including but not limited to: Hydrolec Trash Compactor, Model #HE15264, S/N 080211RP0918, Roach Conveyors, Schurstar Bagger machine Model # 2060-C, Kallfass Film Packing machine Type Universa 500, machine #M01-12.914, etc.   The program only has a one fits all LO/TO procedure and it did not clearly and specifically identify the placement, removal or transfer of Lockout /Tagout devices on each individual type of machine and did not specify the requirements for testing to verify the effectiveness of LO/TO devices and other control measures. Occurred on or about 12/07/2016.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $8149

1910.147 C07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.  a) Frank Donio Inc. - Throughout the Production Area: The employer did not ensure that authorized employees were trained on all aspects of the LOTO program and all specific procedures for each individual machine or equipment identified in the program that was used by each authorized employee as part of their job duty (i.e. Sanitation of machinery), observed on or about 12/07/2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $4,889 · Current $2,500 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Frank Donio Inc. - Production area:  The employer did not provide an eye wash station that provides 15 minutes of continue flow for flushing of the eyes.  Employees working in the production area can come in contact with corrosive chemicals such as Sparchlor Chlorinated Sanitizer and the chlorinated degreaser while performing machine sanitation operations. Occurred on or about 12/07/2016.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4889

1910.253 B02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $4,889 · Current $2,500 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    a) Boccella Precast LLC. - Maintenance area:   Acetylene, Argon and oxygen compressed gas cylinders were not secured from being knocked over, on or about 12/07/2016.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4889

1910.253 B04 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least half hour:  a)  Frank Donio Inc. - Maintenance Area:  Acetylene, propane and oxygen compressed gas cylinders were stored next to each other in the maintenance area  near the doorway, on or about 12/07/2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $4,889 · Current $2,500 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Frank Donio Inc. - Maintenance tool room: Access to an electrical panel was obstructed by welding equipment and stored material. Observed on or about 12/07/2016.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4889

1910.242 B

Other-than-serious 1 instance 10 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.  a)  Frank Donio Inc. - Production/Packing area: Compressed air used for cleaning purposes by employees was approximately 110 p.s.i., occurred on or about 01/07/2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341965689.