KUTZTOWN, PA —
OSHA Inspection: PALRAM 2000, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PALRAM 2000, INCORPORATED in 9735 COMMERCE CIRCLE, KUTZTOWN, PA 19530 (NAICS 326199). OSHA activity number 341977825.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALRAM 2000, INCORPORATED
- Site address
- 9735 COMMERCE CIRCLE
- City
- KUTZTOWN
- State
- PA
- ZIP
- 19530
- Mailing
- 9735 COMMERCE CIRCLE, KUTZTOWN, PA 19530
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 111
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C06 I
- Issued
- Apr 6, 2017
- Abate by
- Apr 21, 2017
- Penalty
- Initial $7,696 · Current $5,196 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Palram 2000, Inc., P3 - On or about December 13, 2016, the employer did not conduct a periodic inspection of their energy control procedure at least annually to ensure that the procedure and the requirement were being followed.
Recent events (2)
- — I (S) $5196
- — Z (S) $7696
1910.147 D04 I
- Issued
- Apr 6, 2017
- Abate by
- Apr 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Palram 2000, Inc., P3 - On or about December 1, 2016, Lockout or tagout devices were not affixed to each energy isolating device by authorized employees on the Bryer Extrusion Lines brand D-78224 cross cutting saw during blade changes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 E01
- Issued
- Apr 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(e)(1): Before lockout tagout devices were removed, the work area was not inspected to ensure that nonessential items had been removed or ensured that machine or equipment components were operationally intact. a) Palram 2000, Inc., P3 - On or about December 1, 2016, after knife blade changing operations were completed on the Bryer Extrusion Lines brand D-78224 cross cutting saw the machine knife carriage metal mesh guards were not replaced prior to re-starting the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02
- Issued
- Apr 6, 2017
- Abate by
- Apr 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were de-energized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): a) Palram 2000, Inc., P3 - On or about December 1, 2016, employees were exposed to contact with electrical parts inside electrical control panel box of the Bryer Extrusion Lines brand, cross cutting saw without the electrical energy source being locked out or tagged out.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Apr 6, 2017
- Abate by
- Apr 21, 2017
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Palram 2000, Inc., P3 - On or about December 13, 2016, the point of operation of the clamp bar / beam on the Bryer Extrusion Lines brand D-78224 cross cutting saw was not guarded by physical barriers, physical devices, or by restricting access to prevent employees from having their fingers, hands or other body parts in the danger zone during operating cycles. b) Palram 2000, Inc., P3 - On or about December 13, 2016, the point of operation of the knife blade on the Bryer Extrusion Lines brand D-78224 cross cutting saw was not guarded by physical barriers, physical devices, or by restricting access to prevent employees from having their fingers, hands or other body parts in the danger zone during operating cycles. c) Palram 2000, Inc., P3 - On or about December 13, 2016, the point of operation of the saw blade on the Bryer Extrusion Lines brand D-78224 cross cutting saw was not guarded by physical barriers, physical devices, or by restricting access to prevent employees from having their fingers, hands or other body parts in the danger zone during operating cycles.
Recent events (2)
- — I (S) $12675
- — Z (S) $12675
1910.147 C04 I
- Issued
- Apr 6, 2017
- Abate by
- Oct 31, 2017
- Penalty
- Initial $45,270 · Current $9,054 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Palram 2000, Inc., P3 - On or about December 1, 2016, procedures for the Bryer Extrusion Lines brand D-78224 cross cutting saw were not developed, documented, and utilized for the control of potentially hazardous energy when employees were performing knife blade changing activities. Palram Panel, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii), which was contained in OSHA inspection number 1088517, citation number 01, item number 02/a and was affirmed as a final order on November 23, 2015, with respect to a workplace located at 9735 Commerce Circle, Kutztown, PA 19530.
Recent events (2)
- — I (S) $9054
- — Z (R) $45270
1910.147 C07 I
- Issued
- Apr 6, 2017
- Abate by
- Oct 31, 2017
- Penalty
- Initial $0 · Current $9,054
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Palram 2000, Inc., P3 - On or about December 1, 2016, adequate training was not provided to ensure that the purpose and function of the energy control program was understood by employees performing blade changing operations on the Bryer Extrusion Lines brand, D-78224 cross cutting saw. Palram Panel, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(7)(I), which was contained in OSHA inspection number 1088517, citation number 01, item number 02/b and was affirmed as a final order on November 23, 2015, with respect to a workplace located at 9735 Commerce Circle, Kutztown, PA 19530.
Recent events (2)
- — I (S) $9054
- — Z (R) $0
More inspections at Palram 2000, Incorporated
View Palram 2000, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341977825.