YORKTOWN, VA —
OSHA Inspection: ISCO INDUSTRIES, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ISCO INDUSTRIES, INC. in CORMAN MARINE CONSTRUCTION BARGE ON YORK RIVER 1901 WATERVIEW RD., YORKTOWN, VA 23692 (NAICS 326191). OSHA activity number 341978831.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ISCO INDUSTRIES, INC.
- Site address
- CORMAN MARINE CONSTRUCTION BARGE ON YORK RIVER 1901 WATERVIEW RD.
- City
- YORKTOWN
- State
- VA
- ZIP
- 23692
- Mailing
- 100 WITHERSPOON ST., LOUISVILLE, KY 40202
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 400
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.334 A02 II
- Issued
- Jun 6, 2017
- Penalty
- Initial $12,675 · Current $8,239 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service. (a) Date of Violation: On or about 12-14-2016 and times prior thereto, located on the HRSD York River Treatment Plant Outfall and Diffuser Project, based out of 1901 Waterview Rd. Yorktown, VA 23692, while onboard Corman Marine Construction, Inc. barge, an employee was exposed to fire and electrical hazards from a MegaMC 2065A Fusion Machine electrical cabinet that had been damaged and temporarily repaired with a coat hangar resulting in the electrical cabinet enclosure door not being able to close to isolate the energized conductors, bus bars, terminals and other internal parts of the electrical equipment. The machines power source cable had been pulled from the cabinet damaging the strain-relief compression clamp. The power cord contained no chaffing protection were it entered the electrical cabinet enclosure. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $8238.75
- — Z (S) $12675
More inspections at Isco Industries, INC.
View Isco Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326191)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341978831.