FLORHAM PARK, NJ —
OSHA Inspection: AYA CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AYA CONSTRUCTION, LLC in 4 VENTURI COURT, FLORHAM PARK, NJ 07932 (NAICS 238170). OSHA activity number 341981330.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AYA CONSTRUCTION, LLC
- Site address
- 4 VENTURI COURT
- City
- FLORHAM PARK
- State
- NJ
- ZIP
- 07932
- Mailing
- 104 PENNINGTON AVENUE APARTMENT 3, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B05 II
- Issued
- Apr 18, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) 4 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 13 feet, 5 inches to the ground below from pump jack scaffolding as the one end of the platform extended over its supports by approximately 7 feet with no end guardrails blocking employees from accessing the cantilevered end. Violation observed on or about 11/18/2016.
Recent events (1)
- — Z (S) $3803
1926.451 G01 VII
- Issued
- Apr 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 4 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 13 feet, 5 inches to the ground below from pump jack scaffolding as the scaffolding was lacking any forms of fall protection such as guard rails or netting and workers were not using any personal fall arrest systems. Violation observed on or about 11/18/2016.
Recent events (1)
- — Z (S) $0
1926.451 F03
- Issued
- Apr 18, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) 4 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 13 feet, 5 inches to the ground below from pump jack scaffolding as a competent person had not inspected the scaffold or its components for defects as shown by the end of the platform extending over its supports by several feet and as shown by the lack of fall protection for employees working on the scaffolding. Violation observed on or about 11/18/2016.
Recent events (1)
- — Z (S) $1630
1926.501 B13
- Issued
- Apr 18, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 4 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 8 feet, 10 inches to the ground below from the sloped roof as no methods of fall protection were in use. Violation observed on or about 11/18/2016.
Recent events (1)
- — Z (S) $3803
1926.1053 B16
- Issued
- Apr 18, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) 4 Venturi Court, Florham Park, NJ. Employees were exposed to falls of up to 8 feet, 10 inches to the ground below from the portable aluminum extension ladder as ladder rungs were bent or broken. Violation observed on or about 11/18/2016.
Recent events (1)
- — Z (S) $2173
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341981330.