BEDFORD, MA —
OSHA Inspection: 1366 TECHNOLOGIES, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of 1366 TECHNOLOGIES, INC in 6 PRESTON COURT, BEDFORD, MA 01730 (NAICS 334413). OSHA activity number 341986719.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 1366 TECHNOLOGIES, INC
- Site address
- 6 PRESTON COURT
- City
- BEDFORD
- State
- MA
- ZIP
- 01730
- Mailing
- 6 PRESTON COURT, BEDFORD, MA 01730
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Apr 25, 2017
- Penalty
- Initial $6,338 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Location - 6 Preston Court, Bedford, MA: On or about 12/21/16, the employer failed to protect employees from fall hazards when working on a roof.
Recent events (2)
- — I (S) $3500
- — Z (S) $6338
1910.157 D06
- Issued
- Apr 25, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $6,338 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.157(d)(6): The employer did not distribute portable fire extinguishers or other containers of Class D extinguishing agent for use by employees so that the travel distance from the combustible metal working area to any extinguishing agent is 75 feet (22.9 m) or less: (a) Location - 6 Preston Court, Bedford, MA: On or about 12/21/16, the employer failed to ensure that a Class D fire extinguisher was available when cutting aluminum with a milling machine.
Recent events (2)
- — I (O) $2000
- — Z (S) $6338
1910.212 A01
- Issued
- Apr 25, 2017
- Penalty
- Initial $8,873 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Location - 6 Preston Court, Bedford, MA: On or about 12/21/16, the employer failed to guard milling machines and ovens when employees were working in areas of point of operation.
Recent events (2)
- — I (S) $5000
- — Z (S) $8873
1910.303 B01 IV
- Issued
- Apr 25, 2017
- Penalty
- Initial $3,802 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from the recognized hazard of damaged insulation. (a) Location - 6 Preston Court Bedford, MA: On or about 1/10/17, the employer failed to ensure that an electrical cord was free of damage.
Recent events (2)
- — I (S) $3500
- — Z (S) $3802
1910.305 A02 I B
- Issued
- Apr 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(i)(B): Temporary wiring was used for a period exceeding 90 days. (a) Location - 6 Preston Court, Bedford, MA: On or about 12/21/16, the employer failed to ensure that a temporary extension cord was used less than 90 days.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 II
- Issued
- Apr 25, 2017
- Abate by
- May 9, 2017
- Penalty
- Initial $711 · Current $400 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested: (a) Location - 6 Preston Court, Bedford, MA: On or about 12/21/16, the employer failed to ensure that electrical safety gloves employees were using were inspected as required.
Recent events (2)
- — I (O) $400
- — Z (O) $711
More inspections at 1366 Technologies, INC
View 1366 Technologies, INC's full OSHA safety record →
More inspections in this industry (NAICS 334413)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341986719.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.