JACKSONVILLE, FL —
OSHA Inspection: PETROLEUM CONTAINMENT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PETROLEUM CONTAINMENT, INC. in 8873 WESTERN WAY, JACKSONVILLE, FL 32256 (NAICS 326199). OSHA activity number 341989853.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PETROLEUM CONTAINMENT, INC.
- Site address
- 8873 WESTERN WAY
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32256
- Mailing
- 8873 WESTERN WAY, JACKSONVILLE, FL 32256
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 48
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1200 H01
- Issued
- Feb 16, 2017
- Penalty
- Initial $4,310 · Current $2,586 Reduced
17502280
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On or about November 1, 2016, two employees from the spraying area were re-assign to work in the lamination area to manually mix styrene-containing resin and Methyl Ethyl Ketone catalyst. The employer failed to train these employees on the specific procedures they needed to follow to protect themselves from the exothermic reaction caused by mixing these two hazardous chemicals, exposing the employees to fire hazards.
Recent events (2)
- — I (S) $2586
- — Z (S) $4310
1910.106 E02 IV D
- Issued
- Feb 16, 2017
- Penalty
- Initial $0 · Current $0
2280
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: a) On or about December 19, 2016, a 55 USGAL drum containing flammable resin was used to dispense into smaller containers with a quarter-turn valve instead of a self-closing valve exposing employees to flammable liquid vapors.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.106 E06 II
- Issued
- Feb 16, 2017
- Penalty
- Initial $0 · Current $0
2280
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with: a) On or about December 19, 2016, at the lamination area, an 55 USGAL drum containing flammable resin was used to dispense the liquid into smaller containers and the employer did not ensure the drum was connected to ground, exposing the employees to an static electricity discharge that may result in a fire.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Feb 16, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about December 19, 2016, at the small boxes lamination area, the access to a portable fire extinguisher was obstructed by materials and product, exposing to fire hazards such as smoke inhalation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Petroleum Containment, INC.
View Petroleum Containment, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341989853.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.