Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MINUTEMAN CONSTRUCTION AND REHAB, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MINUTEMAN CONSTRUCTION AND REHAB, LLC in 686 SUMNER AVE., SPRINGFIELD, MA 01108 (NAICS 238160). OSHA activity number 341993061.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Minuteman Construction and Rehab, LLC — free Get an email when a new federal OSHA severe-injury report for Minuteman Construction and Rehab, LLC is published. One employer, no account, unsubscribe in one click.
Site address
686 SUMNER AVE.
City
SPRINGFIELD
State
MA
ZIP
01108
Mailing
26 UPPER BUTCHER ROAD, ELLINGTON, CT 06029
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.252 A

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 5, 2017
Abate by
Jan 11, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):  (a)  On the roof above the second and third story at 686 Sumner Ave., Springfield, MA 01108, on 12/22/2016 employees performing residential construction (roofing) activities repaired and/or replaced shingles and generated debris but did not use an enclosed chute to dispose of same, resulting in shingle debris striking the ground in and around the work area and the adjoining public sidewalks.
Recent events (1)
  • — Z (S) $3741

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 5, 2017
Abate by
Jan 18, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems.    (a)  On the roof above the first, second and third stories at 686 Sumner Ave., Springfield, MA 01108 on 12/22/2016 employees performing residential construction (roofing) activities were exposed to falls in excess of six feet and were not protected by guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (1)
  • — Z (S) $3741

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 5, 2017
Abate by
Jan 18, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  (a)  At the renovation site at 686 Sumner Ave., Springfield, MA 01108 on 12/22/2016 the employer did not provide a training program for each employee working on the roof above the first, second and third stories who might be exposed to fall hazards.
Recent events (1)
  • — Z (S) $3741

1926.503 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 5, 2017
Abate by
Jan 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record.  (a)  At the renovation site at 686 Sumner Ave., Springfield, MA 01108 on 12/22/2016 employer did not verify fall protection training by preparing a written certification record of employees working on the roof above the first, second and third stories.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 5, 2017
Abate by
Jan 18, 2017
Penalty
Initial $3,741 · Current $3,741
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    (a)  On the front side of the house, along Sumner Ave., at the renovation site at 686 Sumner Ave., Springfield, MA 01108 on 12/22/2016 a portable ladder was used for access to a third story upper landing surface on the roof and the ladder's length did not allow the ladder side rails to extend at least 3 feet above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device was not provided to assist employees in mounting and dismounting the ladder.
Recent events (1)
  • — Z (S) $3741

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341993061.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.