Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPITOL INTERIOR PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAPITOL INTERIOR PRODUCTS, INC. in 4328 RIDGE AVENUE, PHILADELPHIA, PA 19129 (NAICS 444190). OSHA activity number 341998755.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capitol Interior Products, INC. — free Get an email when a new federal OSHA severe-injury report for Capitol Interior Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4328 RIDGE AVENUE
City
PHILADELPHIA
State
PA
ZIP
19129
Mailing
201 ERIE ST, CAMDEN, NJ 08102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.502 D11

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 29, 2017
Abate by
Apr 4, 2017
Penalty
Initial $2,716 · Current $0 Reduced
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:    a) Jobsite - The employer did not ensure that all employees were using lifelines that were protected from abrasions.  Observed on or about 14 OCT 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2716

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Mar 29, 2017
Abate by
Apr 4, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee    a) Jobsite - The employer did not ensure that employees were adequately protected from falls when two employees were tied off of to an anchor strap with a capacity of 5,000 pounds.  Employees were exposed to falls of approximately forty (40) feet.  Observed on or about
Recent events (2)
  • — I (O) $3803
  • — Z (S) $3803

View Capitol Interior Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341998755.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.