Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN SELECT TUBING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN SELECT TUBING, LLC in 4005 DEWITT AVE, MATTOON, IL 61938 (NAICS 423510). OSHA activity number 342002219.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Select Tubing, LLC — free Get an email when a new federal OSHA severe-injury report for American Select Tubing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4005 DEWITT AVE
City
MATTOON
State
IL
ZIP
61938
Mailing
4005 DEWITT AVE, MATTOON, IL 61938
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2017
Abate by
May 22, 2017
Penalty
Initial $6,338 · Current $4,437 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:      On or about December 15, 2016, employees exposed to caught-in and amputation hazards while performing servicing and maintenance activities, and the employer did not conduct an annually periodic inspection.
Recent events (2)
  • — I (S) $4436.6
  • — Z (S) $6338

1910.147 C06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2017
Abate by
May 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:        On or about December 15, 2016, The employer did not certify that a periodic inspection had been performed.  The certification shall include identification of the machine or equipment, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2017
Abate by
May 3, 2017
Penalty
Initial $6,338 · Current $6,211 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:      On or about December 15, 2016, employees were exposed to caught-in and amputation hazards while performing servicing and maintenance activities, and the employer did not provide training to ensure the energy control program was understood, and the employees acquired the knowledge and skills required to isolate the energy sources on the equipment.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $6338

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2017
Abate by
May 3, 2017
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):      a. On or about December 15, 2016, an employee was exposed to caught-in and amputation hazards when performing servicing and maintenance on the Unimac.  The employer failed to implement energy control applications steps as the machine was not shut down or turned off, in order to perform servicing work, per the 1910.147(d)(2) requirements.      b. On or about December 15, 2016, employees were exposed to caught-in and amputation hazards when performing servicing and maintenance on the Unimac. The employer did not ensure interlocks were not being by-passed, during servicing work.     ABATEMENT NOTE: The ANSI B11.19-2010: Performance Criteria for Safeguarding, Section 6. General Safeguarding Requirements, may be used for abatement purposes provided that the safety-related functions (interlocks) prevent employee exposure to hazardous energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8873

View American Select Tubing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342002219.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.