Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US CUSTOMIZED FINISHES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of US CUSTOMIZED FINISHES, LLC in 1175 HIGHWAY 23 SUITE 8, SUWANEE, GA 30024 (NAICS 326130). OSHA activity number 342007259.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Customized Finishes, LLC — free Get an email when a new federal OSHA severe-injury report for US Customized Finishes, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1175 HIGHWAY 23 SUITE 8
City
SUWANEE
State
GA
ZIP
30024
Mailing
1175 HIGHWAY 23, SUITE 8, SUWANEE, GA 30024
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326130
Employees
27
Ownership type
A

8 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).    On or about January 4, 2017: Employees working in the spray area of the facility are exposed to hazards such as but not limited to Helmibond 859 Adhesive and Hemitin Hardener 560, which is a corrosive and contain polyisocyanates. The employer did not assess the workplace for hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.133 A01

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment.   On or about January 4, 2017: Employees working in the spray area of the facility are exposed to eye hazards such as but not limited to Helmibond 859 Adhesive and Hemitin Hardener 560, which is a corrosive and contain polyisocyanates. The employer did not require the use of eye protection when performing mixing and spraying operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.   On or about January 4, 2017: Employees working in the spray areas of the production floor wear a 3M 8210, N95 Particulate Respirator voluntarily when working with chemicals such as but not limited to Helmibond Adhesive 859 and Helmitin Hardener 560, which contain polyisocyanates.  The employer did not conduct an air assessment for the spray areas.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.134 K06

Serious Gravity 5 1 instance 4 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer.   On or about January 4, 2017: Employees working in the spray areas of the production floor wear a 3M 8210, N95 Particulate Respirator when working with chemicals such as but not limited to Helmibond Adhesive 859 and Helmitin Hardener 560.  The employer did not provide training and information on the respirator the employees used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.   On or about January 4, 2017: Employees working in the spray area are exposed to a corrosive when mixing chemicals such as but not limited to Helmibond 859 and Hemitin Hardener 560. The employer did not have an emergency eyewash station in the area.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.1200 E01 I

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.   On or about January 4, 2017: Employees working in the spray areas of the production floor are exposed to chemicals such as but not limited to Sher-Wood Kemvar Plus Surfacer, White; WS45 Lacquer Thinner; Ethyl Acetate; Sure Flow General Purpose Thinner and Helmibond 859 and Helmitin Hardener 560.  The employer did not maintain a list of chemicals with identifier for chemicals used in the workplace.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.1200 H01

Serious Gravity 5 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.   On or about January 4, 2017: Employees working in the spray areas of the production floor are exposed to chemicals such as but not limited to Sher-Wood Kemvar Plus Surfacer, White; WS45 Lacquer Thinner; Ethyl Acetate; Sure Flow General Purpose Thinner and Helmibond 859 and Helmitin Hardener 560, which includes flammables, corrosives, and polyisocyanates.  The employer did not provide training on the chemicals used in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H02 III

Serious Gravity 1 1 instance 5 exposed
Issued
May 26, 2017
Abate by
Jun 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200.   On or about January 4, 2017: Employees working in the spray areas of the production floor are exposed to chemicals such as but not limited to Sher-Wood Kemvar Plus Surfacer, White; WS45 Lacquer Thinner; Ethyl Acetate; Sure Flow General Purpose Thinner and Helmibond 859 and Helmitin Hardener 560, which includes flammables, corrosives, and polyisocyanates.  The employer did not provide to the employees the location of the hazard communication program and safety data sheets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342007259.