Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J AND B ELECTRIC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J AND B ELECTRIC in 5818 WORTH PKWY., SAN ANTONIO, TX 78257 (NAICS 238210). OSHA activity number 342010261.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J and B Electric — free Get an email when a new federal OSHA severe-injury report for J and B Electric is published. One employer, no account, unsubscribe in one click.
Establishment
J AND B ELECTRIC
Site address
5818 WORTH PKWY.
City
SAN ANTONIO
State
TX
ZIP
78257
Mailing
11035 JONES ROAD WEST, HOUSTON, TX 77065
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
24
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 13, 2017
Abate by
Jan 30, 2017
Penalty
Initial $3,563 · Current $3,563
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  On or about January 5, 2017, employees were exposed to a fall hazard of greater than 6 feet to the ground below, while installing light fixtures, without using a personal fall arrest system or any other form of fall protection.
Recent events (1)
  • — Z (S) $3563

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 13, 2017
Abate by
Jan 30, 2017
Penalty
Initial $3,563 · Current $3,563
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed:  On or about January 5, 2017, an employee was exposed to a fall hazard of greater than 6 feet, while installing electric light fixtures, and using a self-supporting ladder as a single straight ladder.
Recent events (1)
  • — Z (S) $3563

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342010261.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.