Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIA/WESTERN REGION/COLORADO RIVER AGENCY

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of BIA/WESTERN REGION/COLORADO RIVER AGENCY in IRRIGATION MAINTENANCE 21051-3 EAST POSTON ROAD, POSTON, AZ 85371 (NAICS 221310). OSHA activity number 342011376.

Watch Bia/Western Region/Colorado River Agency — free Get an email when a new federal OSHA severe-injury report for Bia/Western Region/Colorado River Agency is published. One employer, no account, unsubscribe in one click.
Site address
IRRIGATION MAINTENANCE 21051-3 EAST POSTON ROAD
City
POSTON
State
AZ
ZIP
85371
Mailing
12124 1ST AVENUE, PARKER, AZ 85344
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221310
Employees
83
Ownership type
D

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  West wall of Maintenance Shop, Poston, AZ: On or about 5 January 2017, several full and empty acetylene and oxygen cylinders were not secured.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Maintenance shop, Poston, AZ: On or about 5 January 2017, the rotating chuck on the Jet JDP-20MF drill press was not guarded.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  Maintenance shop, Poston, AZ: On or about 5 January 2017, the Jet JDP-20MF drill press was not securely anchored to the floor.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:   Maintenance shop, Poston, AZ: On or about 5 January 2017, acetylene and oxygen cylinders were stored together without a barrier.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Maintenance shop, Poston, AZ: On or about 5 January 2017, the refrigerator power cord was plugged into a relocatable power tap (RPT).
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  Maintenance shop, Poston, AZ: On or about 5 January 2017, the flexible cord set which powered the DeWalt DW872 Multicutter had a damaged outer jacket.
Recent events (1)
  • — Z (S) $0

View BIA/WESTERN REGION/COLORADO RIVER AGENCY's full OSHA safety record →