RALEIGH, IL —
OSHA Inspection: ELGIN INDUSTRIES DBA CENTRIFUGAL SERVICES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ELGIN INDUSTRIES DBA CENTRIFUGAL SERVICES, INC. in 5595 HWY 34 NORTH, RALEIGH, IL 62977 (NAICS 332710). OSHA activity number 342012051.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELGIN INDUSTRIES DBA CENTRIFUGAL SERVICES, INC.
- Site address
- 5595 HWY 34 NORTH
- City
- RALEIGH
- State
- IL
- ZIP
- 62977
- Mailing
- 5595 HWY 34 NORTH, RALEIGH, IL 62977
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 33
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.95 G06
- Issued
- Apr 10, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $6,338 · Current $4,120 Reduced
811081118130
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : The employer did not obtain annual audiograms in 2016 for employees in the Fabrication Shop who are exposed to an 8-hour time-weighted average of 85 decibels or more.
Recent events (2)
- — I (S) $4119.7
- — Z (S) $6338
1910.95 K02
- Issued
- Apr 10, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $6,338 · Current $4,120 Reduced
811081118130
General-duty citation text
29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program: The employer did not ensure that annual training was conducted for employees in the Fabrication Shop who were included in the hearing conservation program for 2016.
Recent events (2)
- — I (S) $4119.7
- — Z (S) $6338
1910.134 D01 III
- Issued
- Apr 10, 2017
- Penalty
- Initial $6,338 · Current $4,120 Reduced
2587
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: In the Fabrication Shop, the employer did not identify and evaluate the respiratory hazards, including the identification of the contaminant's chemical state and physical form, for employees exposed to welding fumes.
Recent events (2)
- — I (S) $4119.7
- — Z (S) $6338
1910.1026 D01
- Issued
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
06890691
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): The employer did not determine the 8-hour-time-weighted average exposure for employees in the Fabrication shop, who perform welding activities on stainless steel and were exposed to chromium (VI), in accordance with 29 CFR 1910.1026(d)(2) or (d)(3).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Apr 10, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $5,070 · Current $3,296 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers or other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields or weren't required to wear appropriate goggles when flameproof screens or shields were not used: In the Fabrication Shop, employees performed arc welding in the form of metal inert gas (MIG) welding and workers or other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields or weren't required to wear appropriate goggles when flameproof screens or shields were not used.
Recent events (2)
- — I (S) $3295.5
- — Z (S) $5070
1910.305 B01 I
- Issued
- Apr 10, 2017
- Penalty
- Initial $6,338 · Current $4,120 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: In the Fabrication Shop, the electrical cable used to supply power to the dryer testing station was not protected from abrasion as it entered the Test Station Control Box panel.
Recent events (2)
- — I (S) $4119.7
- — Z (S) $6338
1910.1200 G01
- Issued
- Apr 10, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet in the workplace for each hazardous chemical which they use: The employer did not have a safety data sheets for all hazardous chemicals used in the Fabrication Shop, including but not limited to the Plasma Quench 617 solution used for the Plasma Table.
Recent events (2)
- — I (O) $0
- — Z (S) $3802
1910.1200 H01
- Issued
- Apr 10, 2017
- Abate by
- May 25, 2017
- Penalty
- Initial $6,338 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: The employer did not provide effective information and training on the hazardous chemicals in their work area and employees were exposed to hazardous chemicals such as but not limited to Plasma Quench 617, welding gases, hexavalent chromium and welding fumes. Effective information and training was not provided on: 1. The details of the employer's hazard communication program, including how to obtain safety data sheets; and, 2. The hazards associated with welding on stainless steel and steel metals.
Recent events (2)
- — I (O) $0
- — Z (S) $6338
More inspections at Elgin Industries DBA Centrifugal Services, INC.
View Elgin Industries DBA Centrifugal Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342012051.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.