On , OSHA opened a complaint safety inspection of NORTHERN WINDUSTRIAL CO. in 145 DAY STREET, NEWINGTON, CT 06111 (NAICS 423840). OSHA activity number 342012671.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northern Windustrial CO. — free Get an email when a new federal OSHA severe-injury report for Northern Windustrial CO. is published. One employer, no account, unsubscribe in one click.
Site address
145 DAY STREET
City
NEWINGTON
State
CT
ZIP
06111
Mailing
145 DAY STREET, NEWINGTON, CT 06111
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
Employees
12
Ownership type
A

7 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 4 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  A.  On or about January 10, 2017, Main Office:  The side-hinged exterior exit door was not marked with an exit sign.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

1910.37 B06

Serious Gravity 5 3 instances 8 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  A.  On or about January 10, 2017, Fabrication Shop: In the following locations, exits were not provided with illuminated exit signs:  1.  Rear exit door near the garage bay. 2.  Side of the shop.  B.  On or about January 10, 2017, Warehouse:  The exit in the front of the warehouse was not provided with an illuminated exit sign.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.38 B

Serious Gravity 5 1 instance 21 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  A.  On or about January 10, 2017, Facility-Wide:  The employer had not developed or implemented an emergency action plan directing employees to either evacuate the building or use portable fire extinguishers in case of emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2017
Penalty
Initial $3,622 · Current $2,173 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):  A.  On or about January 3, 2017, Fabrication Shop:  The electrical power cordset on the Automaire Fan Company 31-inch metal-encased pedestal fan used for ventilation had damaged insulation and exposed wiring, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $2173.2
  • — Z (S) $3622

1910.303 B02

Serious Gravity 5 3 instances 3 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  A.  On or about January 10, 2017, Fabrication Shop:  In the following locations, wall-mount listed electrical outlet boxes were used to provide pendant power, exposing employees to electric shock hazards:  1.  Fabrication Shop, Rear:  A wall-mount listed 220-V outlet box with perforated knockouts, identified as A 3/5, was used to energize the Victaulic Tool Company VE-268 Series grooving machine.  2.  Fabrication Shop, Rear:  A wall-mount listed two-receptacle 110-V outlet box with perforated knockouts, identified as A1, was used to power fans and lights in the area.  3.  Fabrication Shop, Side:  A wall-mount listed 220-V outlet box with perforated knockouts was used to power a Millermatic 250 welding machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.  On or about January 23, 2017, Fabrication Shop:  The work space in front of the Siemens G4242ML3200CU 3 Phase, 3 Wire, 240V Indoor Load Center was blocked by the storage of three metal pipes; two 5-gallon containers of Valvoline HP 85W-140 Gear Oil; one 5-gallon container of Scales Air Compressor Corporation RE680 Compressor Oil; and two containers of Quikrete Exterior Use Anchoring Cement.  In case of electrical emergency, access to the electrical panel would be delayed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.4 A

Other-than-serious 5 instances 12 exposed
Issued
May 15, 2017
Abate by
Jun 30, 2017
Penalty
Initial $400 · Current $240 Reduced
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent:    Northern Windustrial Co.:  On or about January 10, 2017, the employer did not record the following workplace injuries or illnesses which met the general recording criteria on the OSHA Form 300 or equivalent for the calendar year 2016:    a) On or about February 5, 2016, an employee sustained an elbow injury which resulted in days away from work and restricted duty.  The injury would be appropriately captured with a check in Column H (Days Away), 34 days away in Column K, 92 days restriction in Column L, and a check in Column M1.    b) On or about May 20, 2016, an employee sustained a laceration to the right lower leg which resulted in restricted duty.  The injury would be appropriately captured with a check in Column I (Restricted Duty/Transfer), 9 days restriction in Column L, and a check in Column M1.    c) On or about August 1, 2016, an employee sustained an injury to the left lower back which resulted in days away and restricted duty.  The injury would be appropriately captured with a check in Column H (Days Away), 3 days away in Column K, 3 days restriction in Column L, and a check in Column M1.    d) On or about September 14, 2016, an employee sustained an injury to the right elbow which resulted in restricted duty.  The injury would be appropriately captured with a check in Column I (Restricted Duty/Transfer), 4 days restriction in Column L, and a check in Column M1.    e) On or about September 29, 2016, an employee sustained a laceration injury to the right hand and thumb which resulted in restricted duty.  The injury would be appropriately captured with a check in Column I (Restricted Duty/Transfer), 2 days restriction in Column L, and a check in Column M1.    Abatement Certification and Documentation is required
Recent events (2)
  • — I (O) $240
  • — Z (O) $400

View Northern Windustrial CO.'s full OSHA safety record →