TAMPA, FL —
OSHA Inspection: LOADMASTER ALUMINUM BOAT TRAILERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOADMASTER ALUMINUM BOAT TRAILERS, INC. in 10105 CEDAR RUN, TAMPA, FL 33619 (NAICS 336212). OSHA activity number 342013182.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LOADMASTER ALUMINUM BOAT TRAILERS, INC.
- Site address
- 10105 CEDAR RUN
- City
- TAMPA
- State
- FL
- ZIP
- 33619
- Mailing
- 10105 CEDAR RUN, TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Feb 3, 2017
- Penalty
- Initial $2,463 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) For the Loadmaster Aluminum Boat Trailers facility, as observed on or about 01/09/2017, a Toyota forklift model number 02-5FG30 was operated without a seat belt. This condition exposes employees to potential struck-by hazards.
Recent events (2)
- — I (S) $1477.8
- — Z (S) $2463
1910.212 A01
- Issued
- Feb 3, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $3,622 · Current $2,173 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) For the Loadmaster Aluminum Boat Trailers facility at the welding area, as observed on or about 01/09/2013, a P-50 Piranha Ironworker was used by employees to punch holes in parts. The guard at the punch station was missing exposing employees to potential injury from contact with the punch press point of operation.
Recent events (2)
- — I (S) $2173.2
- — Z (S) $3622
1910.178 L04 III
- Issued
- Feb 3, 2017
- Abate by
- Mar 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) For the Loadmaster Aluminum Boat Trailers facility, as observed on or about 01/09/2017, employees operating forklifts had not received an evaluation/training for forklifts in the last three years.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B02 IV
- Issued
- Feb 3, 2017
- Abate by
- Feb 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) For the Loadmaster Aluminum Boat Trailers Facility, as observed on or about 01/09/2017, A valve cap was missing from a compressed gas oxygen cylinder in storage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B04 III
- Issued
- Feb 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a) For the Loadmaster Aluminum Boat Trailers facility, as observed on or about 01/09/2017, oxygen cylinders were stored adjacent/right next to acetylene fuel gas cylinders.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Feb 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the Loadmaster Aluminum Boat Trailers facility, as observed on or about 01/09/2017, an electrical panel box had its cover removed and was left in that condition with the cover off.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336212)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342013182.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.