OSHA Inspection: FLUOR FEDERAL SOLUTIONS LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FLUOR FEDERAL SOLUTIONS LLC in RADFORD AMMUNITIONS PLANT 4050 PEPPERS FERRY RD, RADFORD, VA 24141 (NAICS 236210). OSHA activity number 342013414.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluor Federal Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Fluor Federal Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
RADFORD AMMUNITIONS PLANT 4050 PEPPERS FERRY RD
City
RADFORD
State
VA
ZIP
24141
Mailing
100 FLUOR DANIEL DR., GREENVILLE, SC 29609
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
1100
Ownership type
A

4 citations on file for this inspection.

1926.760 A01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 24, 2017
Abate by
Feb 17, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  a) 4050 Peppers Ferry Rd, Radford, VA 24141, Boiler Building: On or about December 13, 2016, and times prior thereto, employees that performed work to install metal decking with up to an approximately 32'7"fall distance from eave to lower level that included boiler structures, equipment and the finished floor, were not protected from fall hazards by the use of guardrail systems, safety net systems, or personal fall arrest systems, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $12675
  • — Z (S) $12675

1926.502 D15

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 24, 2017
Abate by
Feb 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  a) 4050 Peppers Ferry Rd, Radford, VA 24141, Boiler Building: On or about December 13, 2016, and times prior thereto, employees that performed work to install metal decking with up to an approximately 32'7" fall distance from eave to lower level, used an anchorage that was not designed, installed and used as part of a complete personal fall arrest system that maintained a safety factor of at least two; and under the supervision of a qualified person, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 III

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 24, 2017
Abate by
Feb 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level.  a) 4050 Peppers Ferry Rd, Radford, VA 24141, Boiler Building: On or about December 13, 2016, and times prior thereto, employees that performed work to install metal decking with up to an approximately 32'7" fall distance from eave to lower level, used Fall Tech 7276WR 20' Web SRLs, that were rigged to an anchor at foot-level such that employees could free fall greater than 6 feet to a lower level, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.761 B

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jan 24, 2017
Abate by
Feb 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761:  a) 4050 Peppers Ferry Rd, Radford, VA 24141, Boiler Building: On or about December 13, 2016, and times prior thereto, employees that performed work to install metal decking with up to an approximately 32'7" fall distance from eave to lower level, were not provided training by a qualified person in site-specific fall hazards and limitations of personal fall arrest systems, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Fluor Federal Solutions LLC's full OSHA safety record →