CLEVELAND, OH —
OSHA Inspection: HYCOMP, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HYCOMP, LLC in 17960 ENGLEWOOD DR., CLEVELAND, OH 44130 (NAICS 326199). OSHA activity number 342013612.
Where did this inspection happen?
- Establishment
- HYCOMP, LLC
- Site address
- 17960 ENGLEWOOD DR.
- City
- CLEVELAND
- State
- OH
- ZIP
- 44130
- Mailing
- 17960 ENGLEWOOD DR., CLEVELAND, OH 44130
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 105
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: On or about January 9, 2017, an employee was observed to be making adjustments inside of a Fadal VMC6535 Vertical Milling Machine (sn: 12002124926) without proper lockout procedures being utilized. The employee had not been listed as an authorized employee and has not received authorized training.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): On or about January 9, 2017, employees were exposed to machine hazards associated with moving parts while performing setup procedures on a Fadal VMC6535 Vertical Milling Machine (sn: 12002124926). Employees were observed to be inside of the mill performing a routine task directly at the point of operation. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the centering procedure [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)] and verification of isolation [(d)(6)], were not implemented to protect employees from machine setup hazards. prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy; shutdown the machine or equipment [(d)(2)]; machine isolation [(d)(3)] Physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $5430.00
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1170). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. b. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC6535 (Shop #1107). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. c. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC6030 (Shop #1138). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. d. On or about January 9, 2017, employees were exposed to the point of operation on Fadal Vertical Milling Machine (Shop #1135). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. e. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1134). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. f. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1169). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. g. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1188). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. h. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1187). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle. i. On or about January 9, 2017, employees were exposed to the point of operation on Fadal VMC4020 (Shop #1077). The equipment did not have a functional interlock in place, allowing doors to be opened during the machine cycle.
Recent events (2)
- — I (S) $5430
- — Z (S) $0
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $9054.00 · Current $5430.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: On or about January 9, 2017, machine specific procedures developed by the company for equipment including, but not limited to mills and lathes did not specifically list steps for verification of isolation.
Recent events (2)
- — I (S) $5430
- — Z (S) $9054
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about January 9, 2017, the employer had not conducted an annual periodic inspection of energy control procedures for equipment including, but not limited to mills and lathes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(4)(i): The medical questionnaire and examinations were not administered confidentially during the employee's normal working hours or at a time and place convenient to the employee: On or about January 9­­, 2017, the employer did not ensure confidentiality in that the employer maintained copies of medical evaluation questionnaires that had been filled out by employees permitted to wear half-mask air purifying respirators while mixing resins.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(6)(i): The employer did not obtain from the physician or other licensed health care professional (PLHCP) a written recommendation regarding the employee's ability to use the respirator: On or about January 9­­, 2017, the employer did not ensure written recommendation had been provided from a physician that states individual employees were permitted to wear half-mask air purifying respirators while mixing resins.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at HYCOMP, LLC
CLEVELAND, OH—2017-10-02 00:00:00
HYCOMP LLC
CLEVELAND, OH—2017-03-02 00:00:00
HYCOMP, LLC
View HYCOMP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
ERIE, PA—2026-07-14 00:00:00
CAPLUGS, LLC
WHATELY, MA—2026-07-13 00:00:00
G & W PRECISION
SANTA ROSA, CA—2026-07-13 00:00:00
WESTERN FIBERGLASS INC.
CONNEAUT, OH—2026-07-13 00:00:00
CONTINENTAL STRUCTURAL PLASTICS
LEOMINSTER, MA—2026-07-10 00:00:00
HOME PRODUCTS INTERNATIONAL - NORTH AMERICA, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16 00:00:00
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15 00:00:00
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15 00:00:00
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15 00:00:00
KENWORTH
Source