OSHA Inspection: INVENTIX MANUFACTURING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INVENTIX MANUFACTURING, LLC in N60 W16350 KOHLER LANE, MENOMONEE FALLS, WI 53051 (NAICS 331522). OSHA activity number 342020229.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inventix Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Inventix Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
N60 W16350 KOHLER LANE
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
N60 W16350 KOHLER LANE, MENOMONEE FALLS, WI 53051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331522
Employees
95
Ownership type
A

5 citations on file for this inspection.

1910.22 D01

Serious Gravity 10 1 instance 3 exposed
Issued
May 2, 2017
Abate by
May 26, 2017
Penalty
Initial $11,408 · Current $9,000 Reduced
29 CFR 1910.22(d)(1): Walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:    (a) The employer did not ensure that the floor surface was clear of rough areas that could cause slips, trips or falls. On or about January 4, 2017, an accident occurred when a cart carrying zinc ingots was caught on the rough floor surface in the manufacturing area.
Recent events (3)
  • — F (S) $9000
  • — C (S) $11408
  • — Z (S) $11408

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
May 2, 2017
Abate by
May 8, 2017
Penalty
Initial $8,149 · Current $0 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    (a) The employer did not ensure that cylinders of compressed gases such as an oxy-fuel torch device was not stored in close proximity to a melting pot for metallic materials.     In section 6.2.1 of CGA P-1-2008, Safe Handling of Compressed Gases In Containers, it states, "Flammable gases shall be stored in well-ventilated areas. Flammable gases shall be stored away from oxidizers, open flames, sparks, and other sources of heat or ignition."
Recent events (3)
  • — F (O) $0
  • — C (S) $8149
  • — Z (S) $8149

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2017
Abate by
May 26, 2017
Penalty
Initial $8,149 · Current $4,000 Reduced
29 CFR 1910.147(c)(4)(ii):     The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    a) The employer did not clearly establish written alternative procedures or methods that provide effective employee protection to lockout tagout, as it pertains  to ANSI/ASSSE Z244.1, to utilize during set-up operations on machines including, but not limited to, the Frech 125-4, Frech 200-2, Frech 200-3, and Frech 500."
Recent events (3)
  • — F (S) $4000
  • — C (S) $8149
  • — Z (S) $8149

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2017
Abate by
May 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) The employer did not ensure that an annual review of the hazardous energy control procedures was conducted.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 2, 2017
Abate by
May 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:   (a) The employer did not ensure that set-up technician employees received training in the control of hazardous energy when conducting set-up operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Inventix Manufacturing, LLC's full OSHA safety record →