NORTHAMPTON, MA —
OSHA Inspection: LFFNO, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LFFNO, INC. in 238 KING STREET, NORTHAMPTON, MA 01060 (NAICS 445310). OSHA activity number 342024064.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LFFNO, INC.
- Site address
- 238 KING STREET
- City
- NORTHAMPTON
- State
- MA
- ZIP
- 01060
- Mailing
- 238 KING STREET, NORTHAMPTON, MA 01060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 445310
- Employees
- 28
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C08
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $5,070 · Current $2,000 Reduced
General-duty citation text
1910.23(c)(8): The employer did not ensure that the cap (if equipped) and top step of a stepladder were not used as steps: (a) In the receiving area at the facility at 238 King Street, Northampton, MA 01060, on or about 1/19/2017 employees accessed the top of the cooler, at a height of approximately 99 inches (8 feet 3 inches) above a lower level by using a seven foot step ladder and using the top step and cap as steps.
Recent events (2)
- — I (S) $2000
- — Z (S) $5070
1910.23 C11
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface had side rails that extended at least 3 feet (0.9 m) above the upper landing surface: (a) In the receiving area at the facility at 238 King Street, Northampton, MA 01060, on or about 1/19/2017 employees used a portable ladder that did not have side rails that extended at least 3 feet (0.9 m) above the upper landing surface (the top of the cooler) to gain access to the top of the cooler.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B01 I
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by guardrail systems, safety net systems, or personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. (a) In the receiving area at the facility at 238 King Street, Northampton, MA 01060, on or about 1/19/2017 employees worked on the unprotected side or edge of the cooler and were approximately 99 inches (8 feet 3 inches) above a lower level and were not protected from falling by guardrail systems, safety net systems, nor personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) In the utility room, at the facility at 238 King Street, Northampton, MA 01060 on 1/12/2017, employee access to the fire extinguisher was obstructed by cases of beverages.
Recent events (2)
- — I (O) $0
- — Z (S) $3802
1910.176 B
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $3,802 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: (b) In the cooler at the facility at 238 King Street, Northampton, MA 01060, on 1/12/2017 wooden beverage storage racks were not anchored to the floor or walls, and more product was placed on the higher shelves making the racks top heavy.
Recent events (2)
- — I (S) $1500
- — Z (S) $3802
1910.304 F01 IV
- Issued
- Feb 15, 2017
- Abate by
- Apr 4, 2017
- Penalty
- Initial $3,802 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: (a) In the utility room, at the facility at 238 King Street, Northampton, MA 01060 on 1/12/2017, overcurrent devices for circuits rated 600 volts, nominal, or less, were blocked by cases of beverages such that they were not readily accessible to each employee or authorized building management personnel.