PENACOOK, NH —
OSHA Inspection: NATURAL PLAYGROUND COMPANY LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NATURAL PLAYGROUND COMPANY LLC in 77 MERRIMACK STREET, PENACOOK, NH 03303 (NAICS 321999). OSHA activity number 342025285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATURAL PLAYGROUND COMPANY LLC
- Site address
- 77 MERRIMACK STREET
- City
- PENACOOK
- State
- NH
- ZIP
- 03303
- Mailing
- 77 MERRIMACK STREET, PENACOOK, NH 03303
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 25
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.95 C01
- Issued
- Apr 11, 2017
- Abate by
- Jul 3, 2017
- Penalty
- Initial $3,622 · Current $1,811 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: Location: Production area On or about 2/13/17 the employer did not develop and implement a hearing conservation program for an employee exposed to a noise level of 88.7 decibels (84% dose) for the 8 hour time weighted average (TWA).
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.134 C02 II
- Issued
- Apr 11, 2017
- Abate by
- May 26, 2017
- Penalty
- Initial $2,897 · Current $1,449 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: Location: production area On or about 2/10/17, the employer did not establish and implement a respiratory program for employees voluntarily using 3M half face elastomeric respirators while sanding natural wood products.
Recent events (2)
- — I (S) $1448.5
- — Z (S) $2897
1910.134 C02 I
- Issued
- Apr 11, 2017
- Abate by
- May 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Location: production area On or about 1/13/17, the employer did not provide the information in Appendix D to employees voluntarily using respirators during woodworking operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 D01
- Issued
- Apr 11, 2017
- Penalty
- Initial $3,622 · Current $1,811 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Or in the alternative: 29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Location: Production area On or about 1/13/2017, table saws used for both rip cuts and cross cuts were used without guards covering the saw blades.
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.213 C02
- Issued
- Apr 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: Location: production area On or about 1/13/17, the employer did not ensure hand fed circular rip saws were quipped with a spreader to prevent material from squeezing the saw blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Apr 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: Location: production area On or about 1/13/17, the employer did not ensure hand fed circular rip saws were quipped with non-kickback devices to prevent material from being thrown back at the operator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Apr 11, 2017
- Abate by
- Jul 3, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about 1/13/17, extension cords were use as permanent power for woodworking equipment including a wood planer, miter saws and table saws. (a) location: miter saws; (b) location: table saws; (c) location: planer.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1910.305 J01 I
- Issued
- Apr 11, 2017
- Abate by
- May 26, 2017
- Penalty
- Initial $2,897 · Current $1,449 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: Location: break area On or about 1/13/17, two 120 volt energized receptacles located approximately 4 feet above the ground had covers which were not secured to the box exposing live parts.
Recent events (2)
- — I (S) $1448.5
- — Z (S) $2897
1910.304 B03 II C 3
- Issued
- Apr 11, 2017
- Abate by
- May 26, 2017
- Penalty
- Initial $2,897 · Current $1,449 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective was used before repaired; Location: production area On or about 1/13/17, the employer did not ensure electrical cords were free from damage: 1. no strain relief and missing ground pin on the drill press 2. missing ground pin on extension cord powering the planner and portable dust collector 3. missing ground pin on portable fan 4. no strain relief on the power cord for the portable dust collector
Recent events (2)
- — I (S) $1448.5
- — Z (S) $2897
1910.303 B02
- Issued
- Apr 11, 2017
- Abate by
- May 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Location: production area at station 3 On or about 1/13/17, a hanging pendent outlet was equipped with knock outs which are designed to be mounted to a fixed surface.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321999)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342025285.