ELMIRA, NY —
OSHA Inspection: HILLIARD CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HILLIARD CORPORATION in 100 WEST 4TH STREET, ELMIRA, NY 14901 (NAICS 333132). OSHA activity number 342025756.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HILLIARD CORPORATION
- Site address
- 100 WEST 4TH STREET
- City
- ELMIRA
- State
- NY
- ZIP
- 14901
- Mailing
- 100 WEST 4TH STREET, ELMIRA, NY 14901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- Employees
- 565
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Apr 10, 2017
- Penalty
- Initial $3,463 · Current $2,597 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: a) Flammable storage room, on or about 1/11/17: Transfer of Reducer # 54, a flammable liquid, from a 55 gallon drum to other smaller containers was not done through a self-closing valve. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2597.25
- — Z (S) $3463
1910.106 E06 II
- Issued
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Flammable storage room, on or about 1/11/17: During liquid transfers a 55 gallon drum of FINISH 1 Economy Thinner was not electrically interconnected from nozzle to smaller containers. Abatement certification must be submitted for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 333132)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342025756.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.