Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AHI SUPPLY, LP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AHI SUPPLY, LP in 2800 N. GORDON STREET, ALVIN, TX 77511 (NAICS 423320). OSHA activity number 342026176.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AHI Supply, LP — free Get an email when a new federal OSHA severe-injury report for AHI Supply, LP is published. One employer, no account, unsubscribe in one click.
Establishment
AHI SUPPLY, LP
Site address
2800 N. GORDON STREET
City
ALVIN
State
TX
ZIP
77511
Mailing
2800 N. GORDON STREET, ALVIN, TX 77511
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
81
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 3 exposed
Issued
May 3, 2017
Abate by
May 30, 2017
Penalty
Initial $11,408 · Current $6,845 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) At Building #5, the point of operation on a KRB Hydraulic Bender, model #11H, serial #0530602, and was not guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $6844.8
  • — Z (S) $11408

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
May 3, 2017
Penalty
Initial $8,149 · Current $4,889 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) At Building #5, the unused openings of a junction box were not closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $4889.4
  • — Z (S) $8149

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
May 3, 2017
Penalty
Initial $8,149 · Current $4,889 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   a) At Building #5, the electrical conduit powering the KRB 11H Pipe Bender lacked strain relief, exposing energized conductors.
Recent events (2)
  • — I (S) $4889.4
  • — Z (S) $8149

View AHI Supply, LP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342026176.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.