Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TENNECO, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TENNECO, INC. in 1601 HIGHWAY 49B NORTH, PARAGOULD, AR 72450 (NAICS 336399). OSHA activity number 342027422.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tenneco, INC. — free Get an email when a new federal OSHA severe-injury report for Tenneco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TENNECO, INC.
Site address
1601 HIGHWAY 49B NORTH
City
PARAGOULD
State
AR
ZIP
72450
Mailing
1601 HIGHWAY 49B NORTH, PARAGOULD, AR 72450
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
1300
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
May 4, 2017
Abate by
May 18, 2017
Penalty
Initial $9,959 · Current $9,900 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about December 21, 2016, in the Tubing Department, the employer failed to conduct periodic inspections and Supervision to ensure correct energy isolation procedures for the Logan hydraulic tube forming Press #2 were followed.  Failure to do so exposed employee to caught-in and amputation hazards.
Recent events (2)
  • — I (O) $9900
  • — Z (S) $9959

1910.147 D02

Serious Gravity 10 1 instance 2 exposed
Issued
May 4, 2017
Abate by
May 18, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:    On or about, December 21, 2016, in the Tubing Department, employees did not implement energy isolation procedures established for the Logan hydraulic tube forming Press #2, MACO/EMSEC 5071, prior to performing troubleshooting and set-up tasks.  Failure to do so exposed employees to pinch point and amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12675