EASTLAKE, OH —
OSHA Inspection: TRU-FAB TECHNOLOGY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRU-FAB TECHNOLOGY INC. in 34820 LAKELAND BLVD, EASTLAKE, OH 44095 (NAICS 332117). OSHA activity number 342027703.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRU-FAB TECHNOLOGY INC.
- Site address
- 34820 LAKELAND BLVD
- City
- EASTLAKE
- State
- OH
- ZIP
- 44095
- Mailing
- 34820 LAKELAND BLVD, EASTLAKE, OH 44095
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332117
- Employees
- 35
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.179 J02 III
- Issued
- Feb 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: a. On or about January 13, 2017, the employer failed to ensure employees performed monthly hook inspections and recorded them prior to allowing them to operate the 5 ton crane serial number HHW14888. b. On or about January 13, 2017, the employer failed to ensure employees performed monthly hook inspections and recorded them prior to allowing them to operate the 5 ton crane serial number HHW14889.
Recent events (1)
- — Z (O) $0
1910.179 J02 IV
- Issued
- Feb 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: a. On or about January 13, 2017, the employer failed to ensure employees performed monthly chain inspections and recorded them prior to allowing them to operate the 5 ton crane serial number HHW14888. b. On or about January 13, 2017, the employer failed to ensure employees performed monthly chain inspections and recorded them prior to allowing them to operate the 5 ton crane serial number HHW14889.
Recent events (1)
- — Z (O) $0
1910.179 N04 I
- Issued
- Feb 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift: a. On or about January 13, 2017, the employer failed to ensure employees performed a daily check of the upper limit switch inspections prior to allowing them to operate the 5 ton crane serial number HHW14888. b. On or about January 13, 2017, the employer failed to ensure employees performed a daily check of the upper limit switch inspections prior to allowing them to operate the 5 ton crane serial number HHW14889.
Recent events (1)
- — Z (O) $0
More inspections at Tru-Fab Technology INC.
View Tru-Fab Technology INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332117)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342027703.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.