Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRYOGENIC SYSTEMS EQUIPMENT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CRYOGENIC SYSTEMS EQUIPMENT, INC. in 2363 136TH STREET, BLUE ISLAND, IL 60406 (NAICS 332420). OSHA activity number 342028941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cryogenic Systems Equipment, INC. — free Get an email when a new federal OSHA severe-injury report for Cryogenic Systems Equipment, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2363 136TH STREET
City
BLUE ISLAND
State
IL
ZIP
60406
Mailing
2363 136TH STREET, BLUE ISLAND, IL 60406
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.132 F01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 6, 2017
Abate by
May 23, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment(PPE):    a.  On or about January 17, 2017, in the facility, employees were not trained to know at least the following:      1.  What PPE is necessary.  2.  When PPE is necessary.  3.  How to properly don, doff, adjust and wear the PPE.  4.  The limitations of PPE.  5.  The proper care, maintenance, useful life and disposal of the PPE.    Employee exposure included but was not limited to 4, 4'methylene bisphenyl isocyanate, struck by from grinding metal and acetone.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.134 E01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 6, 2017
Abate by
Jun 1, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a. On or about January 17, 2017, in the facility, employees were required to wear negative pressure tight fitting respirators.  The employees had not been provided with medical evaluations thereby exposing employees to hazards associated with the use of respirators.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.134 F02

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 6, 2017
Abate by
Jun 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:          a.  On or about January 17, 2017, in the facility, employees were required to wear negative pressure tight fitting respirators.  The employer did not provide employees with a quantitative or qualitative fit test, thereby exposing employees to the hazards associated with welding fumes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 6, 2017
Abate by
May 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a.  On or about January 17, 2017, in the facility, employees were required to wear negative pressure tight fitting respirators.  Employees had not been trained on the proper use of respirators thereby exposing employees to hazards associated with welding fumes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 6, 2017
Abate by
May 23, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced:    a.  On or about January 17, 2017, in the facility, employees had not been trained on the hazards to which they were exposed.  Employee exposure included, but was not limited to 4,4' methylene bisphenyl isocyanate, chromium (VI), and acetone.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

View Cryogenic Systems Equipment, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342028941.