Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HERNANDEZ BUILDERS CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HERNANDEZ BUILDERS CORP. in 7261 PROVIDENCE CT., LONG GROVE, IL 60047 (NAICS 238130). OSHA activity number 342030905.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hernandez Builders Corp. — free Get an email when a new federal OSHA severe-injury report for Hernandez Builders Corp. is published. One employer, no account, unsubscribe in one click.
Site address
7261 PROVIDENCE CT.
City
LONG GROVE
State
IL
ZIP
60047
Mailing
635 JARLATH AVE., DES PLAINES, IL 60018
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Apr 17, 2017
Abate by
May 18, 2017
Penalty
Initial $305 · Current $305
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:     Hernandez Builders Corp., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:     Citation Number                       Item Number                            Abatement Date  01                                            01                                            02/15/2017  01                                            02                                            02/15/2017  01                                            03                                            02/15/2017        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $305

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 9, 2017
Abate by
Feb 15, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:      a) On or about January 17, 2017, employees were exposed to head injury while working without protective helmets in areas below carpentry work activities.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2173

1926.501 B13

Serious Gravity 10 4 instances 7 exposed
Issued
Feb 9, 2017
Abate by
Feb 15, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):            a) On or about January 17, 2017, employees were exposed to the hazard of falling approximately two stories (20 feet) from second story top plates while performing carpentry work without fall protection.     b) On or about January 17, 2017, employees were exposed to the hazard of falling approximately 12 feet from a second story window/wall opening while performing carpentry work without fall protection.  c) On or about January 17, 2017, employees were exposed to the hazard of falling approximately 10 feet from a second story deck while performing carpentry work without fall protection.   d) On or about January 17, 2017, employees were exposed to the hazard of falling approximately 10 feet from a hole in the first story deck while performing carpentry work without fall protection.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

1926.1052 C01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Feb 9, 2017
Abate by
Feb 15, 2017
Penalty
Initial $3,259 · Current $3,259
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:       a) On or about January 17, 2017, employees were exposed to fall hazards of up to approximately 10 feet where a stairway between the first and second level of the building was not equipped with a stairrail system along its unprotected side or edge.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $3259

1926.404 B01 I

Other-than-serious 1 instance 7 exposed
Issued
Feb 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:         a) On or about January 17, 2017, employees were provided with electrical tools and equipment connected by cord and plug to a Honda 6500 watt portable generator without the use of ground fault circuit interrupters or an assured equipment grounding conductor program.           No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342030905.