SYRACUSE, NY —
OSHA Inspection: BITZER SCROLL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BITZER SCROLL, INC. in 6055 COURT STREET ROAD, SYRACUSE, NY 13206 (NAICS 334512). OSHA activity number 342032273.
Where did this inspection happen?
- Establishment
- BITZER SCROLL, INC.
- Site address
- 6055 COURT STREET ROAD
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- 6055 COURT STREET ROAD, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334512
- Employees
- 101
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 B09
- Issued
- Abate by
- Penalty
- Initial $4155.00 · Current $3116.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s) a) Paint Spray Booth, on or about 1/17/17: There was a trash container, spray gun cleaning station and several five gallon pails stored inside the paint spray booth. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $3116.25
- — Z (S) $4155
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary and all scrapers, spuds, or other such tools used for cleaning purposes were not of nonsparking material: a) Paint Spray Booth, on or about 1/17/17: There was a heavy accumulation of combustible residue in the corners of the booth at floor level and cleaning tools were not of a nonsparking material. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5541.00 · Current $4156.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Laboratory, Teardown/Cleaning Area, on or about 1/17/17: Rotating chuck on a Dayton drill press was not guarded. b) Laboratory, Teardown/Cleaning Area, on or about 1/17/17: The unused portions of blade on a Jet horizontal bandsaw were not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $4155.75
- — Z (S) $5541
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $4155.00 · Current $3116.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Assembly, beginning of line, on or about 1/17/17: Airmaster pedestal fan was not grounded in that the ground pin was missing from the plug end. b) Assembly, OP70 Weld, on or about 1/17/17: TPI pedestal fan was not grounded in that the ground wire was disconnected. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $3116.25
- — Z (S) $4155
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: b) Assembly, OP70 Weld, on or about 1/17/17: Flexible cord providing current to a TPI pedestal fan was pulled loose from the frame exposing conductors to damage. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Laboratory, Teardown/Cleaning Area, on or about 1/17/17: Compressed air gun on the workbench measured approximately 80 psi. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BITZER SCROLL, INC.
SYRACUSE, NY—2024-10-08 00:00:00
BITZER SCROLL, INC.
SYRACUSE, NY—2018-05-10 00:00:00
BITZER SCROLL, INC.
View BITZER SCROLL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334512)
RALEIGH, NC—2026-03-03
160633 - ENVIRONMENTAL SERVICES, LLC
ANOKA, MN—2025-10-06
110041 - NVENT MANAGEMENT COMPANY DBA HOFFMAN ENCLOSURES IN
WEST WARWICK, RI—2025-08-29
AMTROL, INC.
CRANBURY, NJ—2025-01-24
BRUNNQUELL IRON WORKS INC
JOHNS RUN, KY—2025-01-02
67659 - DYERS FURNITURE AND APPLIANCE INC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342032273.