Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BITZER SCROLL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BITZER SCROLL, INC. in 6055 COURT STREET ROAD, SYRACUSE, NY 13206 (NAICS 334512). OSHA activity number 342032273.

Watch Bitzer Scroll, INC. — free Get an email when a new federal OSHA severe-injury report for Bitzer Scroll, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BITZER SCROLL, INC.
Site address
6055 COURT STREET ROAD
City
SYRACUSE
State
NY
ZIP
13206
Mailing
6055 COURT STREET ROAD, SYRACUSE, NY 13206
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334512
Employees
101
Ownership type
A

6 citations on file for this inspection.

1910.107 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4155.00 · Current $3116.00 Reduced
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s)  a)  Paint Spray Booth, on or about 1/17/17:  There was a trash container, spray gun cleaning station and several five gallon pails stored inside the paint spray booth.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $3116.25
  • — Z (S) $4155

1910.107 G02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary and all scrapers, spuds, or other such tools used for cleaning purposes were not of nonsparking material:  a)  Paint Spray Booth, on or about 1/17/17:  There was a heavy accumulation of combustible residue in the corners of the booth at floor level and cleaning tools were not of a nonsparking material.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5541.00 · Current $4156.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  Laboratory, Teardown/Cleaning Area, on or about 1/17/17:  Rotating chuck on a Dayton drill press was not guarded.  b)  Laboratory, Teardown/Cleaning Area, on or about 1/17/17:  The unused portions of blade on a Jet horizontal bandsaw were not guarded.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $4155.75
  • — Z (S) $5541

1910.304 G05

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4155.00 · Current $3116.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  Assembly, beginning of line, on or about 1/17/17:  Airmaster pedestal fan was not grounded in that the ground pin was missing from the plug end.  b)  Assembly, OP70 Weld, on or about 1/17/17:  TPI pedestal fan was not grounded in that the ground wire was disconnected.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $3116.25
  • — Z (S) $4155

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  b)  Assembly, OP70 Weld, on or about 1/17/17:  Flexible cord providing current to a TPI pedestal fan was pulled loose from the frame exposing conductors to damage.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  Laboratory, Teardown/Cleaning Area, on or about 1/17/17:  Compressed air gun on the workbench measured approximately 80 psi.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BITZER SCROLL, INC.'s full OSHA safety record →