WEST WARWICK, RI ·
OSHA Inspection: AMTROL, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AMTROL, INC. in 1400 DIVISION ROAD, WEST WARWICK, RI 02893 (NAICS 334512). OSHA activity number 348473448.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMTROL, INC.
- Site address
- 1400 DIVISION ROAD
- City
- WEST WARWICK
- State
- RI
- ZIP
- 02893
- Mailing
- 1400 DIVISION ROAD, WEST WARWICK, RI 02893
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334512
- Employees
- 500
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.107 E03
- Issued
- Feb 5, 2026
- Penalty
- Initial $6,150 · Current $4,305 Reduced
General-duty citation text
29 CFR 1910.107(e)(3): The original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids or liquids with a flashpoint greater than 199.4 �F (93 �C) into spray finishing room(s). (a) Mixing room D66: On or about August 29, 2025, the employer did not ensure that the original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids or liquids with a flashpoint greater than 199.4 �F (93 �C) into spray finishing room.
Recent events (2)
- · I (S) $4305
- · Z (S) $6150
1910.107 G02
- Issued
- Feb 5, 2026
- Penalty
- Initial $7,235 · Current $5,065 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. (a) Spray booth D66: On or about August 29, 2025, the employer did not ensure that all spraying areas were kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.
Recent events (2)
- · I (S) $5064.5
- · Z (S) $7235
1910.107 B05 I
- Issued
- Feb 5, 2026
- Penalty
- Initial $1,355 · Current $949 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges were not maintained so as to indicate or ensure that the required air velocity is maintained. a) Spray booth D66: On or about August 29, 2025, the employer did not ensure that the available gauges, specifically the manometers on the air filter plenum were maintained so as to indicate or ensure that the required air velocity is maintained.
Recent events (2)
- · I (O) $948.5
- · Z (O) $1355
More inspections at Amtrol, INC.