Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: AMTROL, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMTROL, INC. in 1400 DIVISION ROAD, WEST WARWICK, RI 02893 (NAICS 334512). OSHA activity number 348473448.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amtrol, INC. for free Get an email when a new federal OSHA severe-injury report for Amtrol, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AMTROL, INC.
Site address
1400 DIVISION ROAD
City
WEST WARWICK
State
RI
ZIP
02893
Mailing
1400 DIVISION ROAD, WEST WARWICK, RI 02893
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334512
Employees
500
Ownership type
Private (A)

3 citations on file for this inspection.

1910.107 E03

Serious Gravity 1 1 instance 50 exposed
Issued
Feb 5, 2026
Penalty
Initial $6,150 · Current $4,305 Reduced
29 CFR 1910.107(e)(3): The original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids or liquids with a flashpoint greater than 199.4 �F (93 �C) into spray finishing room(s).   (a) Mixing  room D66: On or about August 29, 2025, the employer did not ensure that the original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids or liquids with a flashpoint greater than 199.4 �F (93 �C) into spray finishing room.
Recent events (2)
  • · I (S) $4305
  • · Z (S) $6150

1910.107 G02

Serious Gravity 1 1 instance 50 exposed
Issued
Feb 5, 2026
Penalty
Initial $7,235 · Current $5,065 Reduced
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.  (a) Spray booth  D66: On or about August 29, 2025, the employer did not ensure that all spraying areas were kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.
Recent events (2)
  • · I (S) $5064.5
  • · Z (S) $7235

1910.107 B05 I

Other-than-serious 1 instance 50 exposed
Issued
Feb 5, 2026
Penalty
Initial $1,355 · Current $949 Reduced
29 CFR 1910.107(b)(5)(i): Visible gauges were not maintained so as to indicate or ensure that the required air velocity is maintained.  a) Spray booth  D66: On or about August 29, 2025, the employer did not ensure that the available gauges, specifically the manometers on the air filter plenum were maintained so as to indicate or ensure that the required air velocity is maintained.
Recent events (2)
  • · I (O) $948.5
  • · Z (O) $1355

View Amtrol, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348473448.