Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DELMAR PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DELMAR PRODUCTS, INC. in 400 CHRISTIAN LANE, BERLIN, CT 06037 (NAICS 325211). OSHA activity number 342034600.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Delmar Products, INC. — free Get an email when a new federal OSHA severe-injury report for Delmar Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
400 CHRISTIAN LANE
City
BERLIN
State
CT
ZIP
06037
Mailing
P.O. BOX 504, KENSINGTON, CT 06037
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2017
Abate by
Mar 21, 2017
Penalty
Initial $5,387 · Current $3,770 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    Rotary Slitter:  On, or about, August 23, 2016, an employee suffered serious hand injuries when his hand was pulled into the point of operation on the John Robinson & Company rotary slitter.  The machine was not provided with adequate safeguarding to prevent entry into the point of operation from the in-feed side, out-feed side and top.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $5387

1910.219 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2017
Abate by
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:   Rotary Slitter:  On, or about, January 17, 2017, the shaft end on the John Robinson & Company slitter was not either covered by a stationary guard nor cut back to less than half the diameter and presenting a smooth face.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2017
Abate by
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    Rotary Slitter:  On, or about, January 17, 2017, the spoked drive pulley for the John Robinson & Company slitter was accessible through the existing guard both at the shaft end opening and between the peripheral guard section and the frame of the machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2017
Abate by
Mar 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):     Rotary Slitter:  On, or about, January 17, 2017, the guard provided on the drive belts for the John Robinson & Company slitter was not guarded to prevent entry between the peripheral guard section and the frame of the machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2017
Abate by
Mar 21, 2017
Penalty
Initial $4,310 · Current $3,017 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:     Rotary Slitter:  On, or about, January 17, 2017, the John Robinson & Company slitter was routinely turned on and off using a 220 volt, three phase disconnect box located on the side of the machine.  Recognized and generally accepted electrical standards require that control circuits for industrial machines do not engage more than 120 volts, single phase when operated and that a stop control be provided at the operators normal work position.
Recent events (2)
  • — I (S) $3017
  • — Z (S) $4310

View Delmar Products, INC.'s full OSHA safety record →