Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: N & S SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of N & S SUPPLY in 207 MILTON TURNPIKE, MILTON, NY 12547 (NAICS 332322). OSHA activity number 342036852.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch N & S Supply — free Get an email when a new federal OSHA severe-injury report for N & S Supply is published. One employer, no account, unsubscribe in one click.
Establishment
N & S SUPPLY
Site address
207 MILTON TURNPIKE
City
MILTON
State
NY
ZIP
12547
Mailing
207 MILTON TURNPIKE, MILTON, NY 12547
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
110
Ownership type
A

3 citations on file for this inspection.

1910.178 P01

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 14, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,519 · Current $9,000
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s):      a) Warehouse area - on January 23, 2017, and at times prior, the emergency brake on the employer's Toyota, Model # 42-6FGU18, 3K forklift did not function to stop the vehicle from moving in reverse when engaged.
Recent events (2)
  • — I (S) $9000
  • — Z (S) $6519

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Feb 14, 2017
Abate by
Mar 13, 2017
Penalty
Initial $6,519 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    a) Shop Area - on January 23, 2017, and at times prior, the markings to indicate purpose for each circuit breaker in the main shop panel were missing, or illegible.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6519

1910.303 G01 I A

Other-than-serious 1 instance 5 exposed
Issued
Feb 14, 2017
Abate by
Feb 21, 2017
Penalty
Initial $4,889 · Current $0 Reduced
29 CFR 1910.303(g)(1)(i)(A): Working space about electric equipment rated 600 volts, nominal, or less was not provided with the minimal depth in the direction of access to live parts as indicated in Table S-1:      a) Shop area - on January 23, 2017, and at times prior, an electrical panel was blocked by a shelf placed on one side, and misc equipment placed on the floor close to the panel.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4889