Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VAUGHAN MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VAUGHAN MASONRY, INC. in 315 WISE CENTER DRIVE, MISSISSIPPI STATE, MS 39762 (NAICS 238140). OSHA activity number 342036944.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vaughan Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Vaughan Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
315 WISE CENTER DRIVE
City
MISSISSIPPI STATE
State
MS
ZIP
39762
Mailing
53 MCKAY DRIVE, COLUMBUS, MS 39702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
16
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2017
Penalty
Initial $4,310 · Current $4,310
29 CFR 1926.451(b)(1): Each platform on all working levels of the scaffold was not fully planked or decked between the front uprights and the guardrail supports.    (a)  East Mechanical Room - On or about January 18, 2017 one bay masonry scaffold was not fully planked. Employees exposed to a fall height of 13 feet 11 inches.
Recent events (3)
  • — A (S) $4310
  • — I (S) $2586
  • — Z (S) $4310

1926.451 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).  (a)  East Mechanical Room - On or about January 18, 2017 one bay masonry scaffold planking did not extend at least 6 inches past the end supports.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2017
Penalty
Initial $4,310 · Current $4,310
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    (a)  East Mechanical Room - On or about January 18, 2017 employees used the supports of a one bay masonry scaffold to access the top level at a fall height of 13 feet 11 inches. The scaffold did not have a ladder attached to access the work level.
Recent events (3)
  • — A (S) $4310
  • — I (S) $2586
  • — Z (S) $4310

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2017
Penalty
Initial $4,310 · Current $4,310
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section:      (a)  East Mechanical Room - On or about January 18, 2017 employees were installing cinder blocks from a one bay masonry scaffold without fall protection. Employees were exposed to a fall height of 13 feet 11 inches.
Recent events (3)
  • — A (S) $4310
  • — I (S) $2586
  • — Z (S) $4310

1926.1051 A

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 8, 2017
Penalty
Initial $3,232 · Current $3,232
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.    (a)  East Mechanical Room - On or about January 18, 2017 employees entered the room from the outside at a height of 24 inches without a access to break the elevation.  -
Recent events (3)
  • — A (S) $3232
  • — I (S) $1742
  • — Z (S) $3232

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342036944.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.