Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: URBAN WAVERLY AMIS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of URBAN WAVERLY AMIS, LLC in 412 SOUTH 13TH STREET, PHILADELPHIA, PA 19147 (NAICS 722511). OSHA activity number 342038999.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Urban Waverly Amis, LLC — free Get an email when a new federal OSHA severe-injury report for Urban Waverly Amis, LLC is published. One employer, no account, unsubscribe in one click.
Site address
412 SOUTH 13TH STREET
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
5000 SOUTH BROAD STREET, PHILADELPHIA, PA 19112
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722511
Employees
26
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 7, 2017
Abate by
Jul 19, 2017
Penalty
Initial $8,873 · Current $6,655 Reduced
1910.147(c)(1)  Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) Jobsite - The employer did not establish and implement a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energization, start up or release of stored energy could occur and cause injury, the machine or equipment was isolated form the energy source and rendered inoperative.  Noted on or about 1/18/17.
Recent events (3)
  • — F (S) $6654.75
  • — C (S) $8873
  • — Z (S) $8873

1910.147 C07 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jul 7, 2017
Abate by
Jul 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.  a) Jobsite: The employer did not develop and implement adequate training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired.  Noted on or about 1/18/17.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jul 7, 2017
Abate by
Jul 13, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) Jobsite: Kitchen - An employee was exposed to entanglement hazards from the mixer shaft of a P6 Automatic Fresh Pasta Machine as the machine's safety cover and safety micro switch were in disrepair.  An employee manually preparing food in the tank of the pasta machine suffered severe injuries when his arm got entangled with the machine's mixer shaft that did not automatically shut off when the safety cover was lifted and the safety micro switch activated.  Noted on or about 1/18/17.
Recent events (3)
  • — F (O) $8873
  • — C (S) $8873
  • — Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342038999.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.