WASHINGTON, DC —
OSHA Inspection: GARNICA CONSTRUCTION, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARNICA CONSTRUCTION, LLC. in 1402 H STREET, NE, WASHINGTON, DC 20002 (NAICS 238130). OSHA activity number 342039179.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARNICA CONSTRUCTION, LLC.
- Site address
- 1402 H STREET, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 11431 CHERRY HILL ROAD, #301, BELTSVILLE, MD 20705
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.21 B02
- Issued
- Mar 2, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Job Site - Employees were not provided with training in the recognition and avoidance of hazards as evidenced by employees being exposed to hazards such as but not limited to; employee using a portable electric grinder to cut steel and the flange guard was not being used and not wearing eye protection on or about 01/18/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2716
1926.95 A
- Issued
- Mar 2, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) Third Floor Main Hallway - An employee was observed cutting a piece of black iron bridging using a Makita portable electric grinder, model number 1315, serial number 9557PB, and not wearing eye protection, on or about 01/18/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.300 B01
- Issued
- Mar 2, 2017
- Abate by
- Mar 8, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Third Floor Main Hallway - An employee was observed using a Makita portable electric grinder, model number 1315, serial number 9557PB to cut steel bridging and not using the flange guard, on or about 01/18/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
- — Z (S) $2716
1926.404 B01 I
- Issued
- Mar 2, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Third Floor Main Hallway - An employee was observed cutting steel bridging using a Makita portable electric grinder model number 1315, serial number 9557PB and not provided with a ground fault circuit interrupter, on or about 01/18/2017. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $2716
1926.1052 C12
- Issued
- Mar 2, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) Stairway #2 - Employees were observed on the stairway landing after exiting the ladder and exposed to a 16 foot fall hazard to a concrete slab below, on or about 01/18/2017. No abatement certification or documentation required for this item.