Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CPM CONSTRUCTORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CPM CONSTRUCTORS in EAST END SULLIVAN STREET, EASTPORT, ME 04631 (NAICS 237310). OSHA activity number 342040920.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CPM Constructors — free Get an email when a new federal OSHA severe-injury report for CPM Constructors is published. One employer, no account, unsubscribe in one click.
Establishment
CPM CONSTRUCTORS
Site address
EAST END SULLIVAN STREET
City
EASTPORT
State
ME
ZIP
04631
Mailing
P.O. BOX B, FREEPORT, ME 04032
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
25
Ownership type
A

2 citations on file for this inspection.

1926.502 D23

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 17, 2017
Abate by
Feb 28, 2017
Penalty
Initial $5,387 · Current $3,770 Reduced
29 CFR 1926.502(d)(23): Personal fall arrest systems shall not be attached to guardrail systems, nor shall they be attached to hoists except as specified in other subparts of this Part.      Eastport Breakwater - Employees were utilizing the middle guard wire as their fall arrest attachment point.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $5387

1926.1416 D03 II A

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Feb 17, 2017
Abate by
Feb 24, 2017
Penalty
Initial $5,387 · Current $0 Reduced
29 CFR 1926.1416(d)(3)(ii)(A): Lattice boom cranes manufactured after Feb 28, 1992, was not equipped with a device that could either automatically prevent damage and load failure from contact between the load block and the boom tip or warn the operator in time for the operator to prevent two-blocking.    Breakwater - The anti two-blocking device was not replaced on the Terex HC110 lattice boom crane before returning to normal operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5387

View CPM Constructors's full OSHA safety record →