DELAWARE, OH —
OSHA Inspection: SAMUEL TORRES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAMUEL TORRES in 4898 ROYAL BIRKDALE DRIVE, DELAWARE, OH 43015 (NAICS 238130). OSHA activity number 342041571.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMUEL TORRES
- Site address
- 4898 ROYAL BIRKDALE DRIVE
- City
- DELAWARE
- State
- OH
- ZIP
- 43015
- Mailing
- 3735 BRIGGS ROAD, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Apr 24, 2017
- Abate by
- May 4, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On or about January 20, 2017, at the residential job site, Lot 8100, an employee using a nail gun while performing framing activities in the roof trusses was not protected with safety glasses or equivalent eye protection.
Recent events (1)
- — Z (S) $2716
1926.404 F06
- Issued
- Apr 24, 2017
- Abate by
- May 4, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous: a. On or about January 20, 2017, at the residential job site, Lot 8100, the flexible cord for the multi-port receptacle used to supply power to equipment was missing the ground prong, thereby exposing employees to an electrical hazard.
Recent events (1)
- — Z (S) $1630
1926.405 A02 II I
- Issued
- Apr 24, 2017
- Abate by
- May 4, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage: a. On or about January 20, 2017, at the residential job site, Lot 8100, the protective covering on the flexible cord for the Makita circular saw was damaged with exposed copper wiring, thereby exposing employees to an electrical hazard.
Recent events (1)
- — Z (S) $1630
1926.501 B13
- Issued
- Apr 24, 2017
- Abate by
- May 4, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: a. On or about January 20, 2017, at the residential job site, Lot 8100, an employee performing framing activities on the roof trusses was not protected by a guardrail system, safety net system, or personal fall arrest system, thereby exposing the employee to a fall hazard of greater than 10 feet.
Recent events (1)
- — Z (S) $3803
1926.1053 B04
- Issued
- Apr 24, 2017
- Abate by
- May 4, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed: a. On or about January 20, 2017, at the residential job site, Lot 8100, a stepladder was used by an employee to access the roof trusses, thereby exposing the employee to a fall hazard of less than 10 feet.
Recent events (1)
- — Z (S) $2173
More inspections at Samuel Torres
View Samuel Torres's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342041571.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.